> For example in the case of the max7219 libraries: it 'knows' which SPI 
> mode is the one and only right mode for the max7219, so why bother the 
> user of the max7219 with having to find out which SPI mode is the right 
> one? 

I do agree that we should not bother the user with much of these things, 
and I'd like to see your solution.

If I use max7219, as well as another chip that uses a different mode, 
whatever is included 2nd would override the mode of the first, therefore 
the first included device would not work. How should we work around this? 
Are there a series of checks we can do to avoid this?

-- 