I was able to get my 3490 drives online to the test LPAR O/S.  I didn't actually run 
anything to allocate/use a drive but the CHPID, PATH, and devices all came online.

My 3490's are parallel channel attached and the CHPID is defined as reconfigurable.  I 
varied the devices and path offline and configured the CHPID offline to the production 
LPAR O/S.

I went to the H30's SE and re-assigned the CHPID to the test LPAR.  I was able to 
config the CHPID online and vary the PATH and devices online to the test LPAR O/S.

----------------------------------------------------------------------