SRD - Inductive product - European limitations ?

2003-08-01 Thread Pierre Selva
, safety, radio, eco-design - product regulations) 1 rue des Essarts 38610 GIERES - FRANCE Pierre SELVAPhone : 33 (0)4 38 370 007 Gérant Fax : 33 (0)4 38 371 004 e-mail : mailto:pierre.se...@e-labs.fr

Class 2 circuit requirements - UL1310

2003-02-11 Thread Pierre SELVA
Hello, As I don't have the UL1310, I need some help. Can somebody give me, very shortly, the main requirements wich define a class 2 circuit, knowing this should apply to a 24VDC power supply output ? Many thanks, Pierre Selva This message is from the IEEE EMC Society Product Safety

UL508 and UL60950

2003-02-04 Thread Pierre SELVA
in a complete UL508 product. In other words, do we have to demonstrate compliance of the included product to UL 508 if it’s UL60950 certified ? For example, can we use UL60950 industrial computers in a UL 508 complete product ? Any input is welcome Many thanks in advance. Pierre Selva This message is from

Looking for information

2002-11-28 Thread Pierre SELVA
for your cooperation. Best regards, Pierre Selva --- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your subscription, send mail

RE: EMC and safety for Head Lamp

2002-11-22 Thread Pierre SELVA
lighting, I don't see any other UL applicable standards. Do you (or somebody here) believe that it exists an other applicabl safety standard ? Once more, thanks for you cooperation. Regards, Pierre Messsage du 22/11/2002 10:34 De : Peter Merguerian pmerguer...@itl.co.il A : 'Pierre SELVA' e.l

RE: EMC and safety for Head Lamp

2002-11-22 Thread Pierre SELVA
be tested against EMC standard, if any applied. I understand Gary will check this point. Furthermore, when intrinsic safety is wanted, I have to comply with UL 783 safety standard. Am I right ? I thank you a lot for your cooperation, Best regards, Pierre Selva Messsage du 21/11/2002 20:22 De

EMC and safety for Head Lamp

2002-11-20 Thread Pierre SELVA
comments, Best regards, Pierre Selva eLABs --- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your subscription, send mail

Abnormal test and SELV / 60950

2002-08-29 Thread Pierre SELVA
the SELV values. What is your opinion on this matter ? Thanks a lot for your answers, Pierre Selva eLABs (emc, safety, radio, eco-design - product regulations) 1 rue des Essarts 38610 GIERES - FRANCE e-mail : e.l...@wanadoo.fr --- This message is from

IEC 60601-1

2002-07-29 Thread Pierre SELVA
Hello, As all the safety standards, IEC 60601 defines the creepage and clearance distances regarding the working voltage of the considered insulation. In a switching power supply, designed for medical product, one of my customer has designed the creepage and clearance distances to be compliant

FCC and Professional Scanner : Verification or certification

2002-07-26 Thread Pierre SELVA
. Thanks for your help, Best regards, Pierre eLABs (emc, safety, radio - product regulations) Pierre SELVA 18 Rue Marceau Leyssieux 38400 SAINT MARTIN D'HERES - FRANCE Phone : 33 (0)6 76 63 02 58 Fax : 33 (0)6 61 37 87 48 e-mail : e.l...@wanadoo.fr

FCC Authorization (Form 731) for ITE class B ; Do I need a TCB ?

2002-07-01 Thread Pierre SELVA
I use the Electronic Filling System of FCC directly, as I did it some years ago ? I a TCB is needed, TCB members can contact me offline for business matters. Thanks for your collaboration, Pierre Selva eLABs e-mail : e.l...@wanadoo.fr --- This message

Speaker connected to a PC - FCC rules

2002-04-16 Thread Pierre SELVA (eLABs)
Dear people, I need to know if the FCC rules (part 15) applied to the following product : Speaker peripheral connected to a personal computer. This product has its own power supply. It's connected to the PC via the speaker output. Reading the Bulletin 62, pages 10 and 12, I'm not sure this

Flame rating

2002-02-21 Thread Pierre SELVA (eLABs)
, but I cannot find this new one, which is issued, I believe, from the 60590. Many thanks, Pierre Selva eLABs (emc, safety, radio, eco-design - product regulations) 18 Rue Marceau Leyssieux 38400 SAINT MARTIN D'HERES - FRANCE Pierre SELVAPhone : 33 (0)6 76 63 02

RE: Flammabilty requirement for cloth used on loudspeaker / UL6500

2002-02-13 Thread Pierre SELVA (eLABs)
Rich, Thanks for the information. Unfortunately, Hexamine is temporarely unavailable from IMSPLUS, and, furthermore, this product cannot be sold outside the US. If somebody knows another source, he's welcome ! -Message d'origine- De : Rich Nute [mailto:ri...@sdd.hp.com] Envoyé :

Flammabilty requirement for cloth used on loudspeaker / UL6500

2002-02-13 Thread Pierre SELVA (eLABs)
if this information can be provided by the cloth manufacturer ? Many thanks for your answers, Pierre SELVA eLABs (emc, safety, radio, eco-design - product regulations) 18 Rue Marceau Leyssieux 38400 SAINT MARTIN D'HERES - FRANCE Pierre SELVAPhone : 33 (0)6 76 63 02 58

IEC 601-1 : Insulation between applied part and signal input

2001-12-27 Thread Pierre SELVA
and best whishes !) eLABs Pierre SELVA 18 Rue Marceau Leyssieux 38400 SAINT MARTIN D'HERES - FRANCE Phone : 33 (0)6 76 63 02 58 Fax : 33 (0)6 61 37 87 48 e-mail : e.l...@wanadoo.fr ps.el...@laposte.net ==

Cooking induction apparatus and FCC

2001-05-21 Thread Pierre SELVA
(electronic submittal), or should I have to go to a TCB ? In advance, I thank you a lot for your answers, Best regards from France Pierre SELVA 2 route de la Grobelle 73000 JACOB BELLECOMBETTE - France Tel : 33 (0)6 60 52 04 96 Fax : 33 (0)6 61 37 87 48 e-mail

Safety in Oregon

2001-01-27 Thread Pierre SELVA
, Pierre SELVA 2 route de la Grobelle 73000 JACOB BELLECOMBETTE Tel : 33 (0) 6 60 52 04 96 Fax : 33 (0)6 61 37 87 48 e-mail : pierre.se...@worldonline.fr

EN60065 and fire enclosure

2000-11-23 Thread Pierre SELVA
you explain me what is missing in my analysis ? I thank you very much in advance for all your valuable inputs. Best regards, Pierre SELVA 2 route de la GROBELLE 73000 JACOB BELLECOMBETTE - FRANCE Fx : 33 (0)6 61 37 87 48 GSM : 33 (0)6 60 52 04 96 e-mail

RE: Looking for inverter 230V/-48VDC

2000-09-07 Thread Pierre SELVA
Mitchell [mailto:dan_mitch...@condordc.com] Sent: Wednesday, September 06, 2000 5:33 PM To: Pierre SELVA Subject: Re: Looking for inverter 230V/-48VDC Sounds as if you are really looking for a AC to DC Power Supply. An inverter usually goes the other way, DC to AC and is speced by the number

Looking for inverter 230V/-48VDC

2000-09-05 Thread Pierre SELVA
Hello all, For one of my customer, I'm looking for an inverter 115/230Vac to -48VDC which is UL, cUL certified and CE compliant. If you know some providers, thanks for your inputs. Best regards, Pierre. Pierre SELVA 2 route de la GROBELLE 73000 JACOB

EMC and safety worldwide market

2000-07-12 Thread Pierre SELVA
, == Pierre SELVA 2 route de la Grobelle 73000 JACOB BELLECOMBETTE - France Tel : 33 4 79 60 82 19 GSM : 33 6 60 52 04 96 Fax : 33 6 61 37 87 48 e-mail : pierre.se...@worldonline.fr =

Re: FCC part 15 class B, testing

1999-11-24 Thread Pierre Selva
test, AND we perform final measurements on our OATS. This process is fully accepted by FCC. Regards, Pierre SELVA -Original Message- From: Colgan, Chris chris.col...@tagmclarenaudio.com To: 'ron_cher...@densolabs.com' ron_cher...@densolabs.com; emc-p...@majordomo.ieee.org emc-p

Conducted emission for an intentional radiator

1999-11-08 Thread Pierre Selva
by the product, except the one needed for functional purpose ? Do you know if FCC Part 15 or ANSI C63.4 authorizes this kind of procedure ? I thank you a lot for your answers, Meilleures salutations de France, == Pierre SELVA Laboratory responsible SMEE Actions Mesures

Insulation between 12VDC and 230V - IEC65

1999-09-08 Thread Pierre Selva
, and how did you solve it ? In advance, I thank you a lot for your answers, Best regards Pierre Selva Laboratory responsible EMC and Safety laboratory SMEE Actions MesuresPh : 33 4 76 65 76 50 ZI

80/80 calculation rules for CISPR22/EN55022

1999-08-26 Thread Pierre Selva
, will be of great value (80/80 calculation, of course !!) Best regards, Pierre Selva Laboratory responsible EMC and Safety laboratory SMEE Actions MesuresPh : 33 4 76 65 76 50 ZI des Blanchisseries

RE: CE Marking requirements

1999-08-25 Thread Pierre Selva
marking on your board. Pierre Selva Laboratory responsible EMC and Safety laboratory SMEE Actions MesuresPh : 33 4 76 65 76 50 ZI des Blanchisseries Fx : 33 4 76 66 18 30 38500