Firewll has a ttl on your media nat session.

What is it?
============================
Tony Graziano, Manager
Telephone: 434.984.8430
Fax: 434.984.8431

Email: [email protected]

LAN/Telephony/Security and Control Systems Helpdesk:
Telephone: 434.984.8426
Fax: 434.984.8427

Helpdesk Contract Customers:
http://www.myitdepartment.net/gethelp/

----- Original Message -----
From: [email protected]
<[email protected]>
To: [email protected] <[email protected]>
Sent: Fri Oct 15 00:53:43 2010
Subject: Re: [sipx-users] system configs

I think that's what they've done, but apparently the calls don't drop on
their system.

Myself, I think they are on the wrong track. They are saying it's a
problem with their Underlying Carrier and that's what they are
attempting to debug.

What I see is that Sipx sends an INVITE with SE of 600 (I reduced it
from the original 1800 to make it easier to debug). They send a 200 OK
with no SE header so no Session Timer will be in effect. And, they claim
that they don't use Session Timers. Yet they send a BYE after 600
seconds. I've tried different valuse: the original default of 1800, and
660 just to confirm it. They always send the BYE at the end of that
time.

On Thu 14.Oct.10 23:51, Tony Graziano wrote:
>But why don't you have them setup the system and a test trunk of their own.
>
>That should be so much easier.
>============================
>Tony Graziano, Manager
>Telephone: 434.984.8430
>Fax: 434.984.8431
>
>Email: [email protected]
>
>LAN/Telephony/Security and Control Systems Helpdesk:
>Telephone: 434.984.8426
>Fax: 434.984.8427
>
>Helpdesk Contract Customers:
>http://www.myitdepartment.net/gethelp/
>
>----- Original Message -----
>From: Tony Graziano <[email protected]>
>To: [email protected] <[email protected]>
>Sent: Thu Oct 14 18:10:30 2010
>Subject: Re: [sipx-users] system configs
>
>You would have to send them a backup and theywould have everything.
>
>Pins, sip passwords,  everything except root passwd.
>
  >I would stay away from that.
>============================
>Tony Graziano, Manager
>Telephone: 434.984.8430
>Fax: 434.984.8431
>
>Email: [email protected]
>
>LAN/Telephony/Security and Control Systems Helpdesk:
>Telephone: 434.984.8426
>Fax: 434.984.8427
>
>Helpdesk Contract Customers:
>http://www.myitdepartment.net/gethelp/
>
>----- Original Message -----
>From: [email protected]
><[email protected]>
>To: [email protected] <[email protected]>
>Sent: Thu Oct 14 17:00:13 2010
>Subject: [sipx-users] system configs
>
>I'm still working with Flowroute on a dropped call problem. They have
>setup a SipX test system, but are not able to duplicate the problem.
>They would like me to send my configuration files so they can load them
>into their system.
>
>1. Is this possible? What would I need to send, and is there a way to
>only include the config for the Flowroute gateway?
>
>2. What are the security/privacy worries with doing this?
>

-- 
Dan McDaniel
[email protected]
Key fingerprint = CAEC B8D9 3701 86CF D3B2  1E99 D8BB F217 455C AD36
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to