I did, evidently. I had neurosurgery on Thursday and was in the hospital when you sent it. I'll try to look at it later today or tomorrow.
On Mon, Oct 18, 2010 at 2:04 PM, Dan McDaniel <[email protected]> wrote: > Tony, I sent a trace and pcap on Friday via PM. Did you ever receive it? > > > Dan > > On Fri 15.Oct.10 14:36, Tony Graziano wrote: > >> I can try to look at this if you want to share it. >> >> On Fri, Oct 15, 2010 at 2:27 PM, Dan McDaniel <[email protected]> wrote: >> >> There's no template for Flowroute. It's manual. I think I started with >>> the Vitelity template and modified it. >>> >>> On Fri 15.Oct.10 06:01, Tony Graziano wrote: >>> >You might also consider totating the logs on sipx at the same time and >>> do >>> a >>> >merge-logs for a siptrace of the same period. >>> > >>> >I'm not at a system (phone), but is flowroute a trmplate or it is a >>> manual >>> >gateway? >>> >============================ >>> >Tony Graziano, Manager >>> >Telephone: 434.984.8430 >>> >Fax: 434.984.8431 >>> > >>> >Email: [email protected] >>> > >>> >LAN/Telephony/Security and Control Systems Helpdesk: >>> >Telephone: 434.984.8426 >>> >Fax: 434.984.8427 >>> > >>> >Helpdesk Contract Customers: >>> >http://www.myitdepartment.net/gethelp/ >>> > >>> >----- Original Message ----- >>> >From: Tony Graziano <[email protected]> >>> >To: [email protected] <[email protected]> >>> >Sent: Fri Oct 15 03:21:12 2010 >>> >Subject: Re: [sipx-users] system configs >>> > >>> > I didn't know what firewall you are using. Pfsense will keep the state >>> >open, there in no setting needed. >>> > >>> >Their inhouse test is going through nat? And has a firewall? If not >>> their >>> >test is flawed. Do a wan pcap to port 5060, full detail and specify >>> their >>> >gateway address and run it beginning at 18 minutes into a call that >>> drops >>> >in20. They should do the same. >>> >============================ >>> >Tony Graziano, Manager >>> >Telephone: 434.984.8430 >>> >Fax: 434.984.8431 >>> > >>> >Email: [email protected] >>> > >>> >LAN/Telephony/Security and Control Systems Helpdesk: >>> >Telephone: 434.984.8426 >>> >Fax: 434.984.8427 >>> > >>> >Helpdesk Contract Customers: >>> >http://www.myitdepartment.net/gethelp/ >>> > >>> >----- Original Message ----- >>> >From: [email protected] >>> ><[email protected]> >>> >To: [email protected] <[email protected]> >>> >Sent: Fri Oct 15 01:32:01 2010 >>> >Subject: Re: [sipx-users] system configs >>> > >>> >I'm not familiar with that setting. Where is it found in pfSense? >>> >(Although this problem also occurs with a Vyatta firewall). >>> > >>> >And I'm a little confused as to how the firewall would know the value in >>> >the SE header. Can you elaborate? >>> > >>> >On Fri 15.Oct.10 00:59, Tony Graziano wrote: >>> >>Firewll has a ttl on your media nat session. >>> >> >>> >>What is it? >>> >>============================ >>> >>Tony Graziano, Manager >>> >>Telephone: 434.984.8430 >>> >>Fax: 434.984.8431 >>> >> >>> >>Email: [email protected] >>> >> >>> >>LAN/Telephony/Security and Control Systems Helpdesk: >>> >>Telephone: 434.984.8426 >>> >>Fax: 434.984.8427 >>> >> >>> >>Helpdesk Contract Customers: >>> >>http://www.myitdepartment.net/gethelp/ >>> >> >>> >>----- Original Message ----- >>> >>From: [email protected] >>> >><[email protected]> >>> >>To: [email protected] <[email protected]> >>> >>Sent: Fri Oct 15 00:53:43 2010 >>> >>Subject: Re: [sipx-users] system configs >>> >> >>> >>I think that's what they've done, but apparently the calls don't drop >>> on >>> >>their system. >>> >> >>> >>Myself, I think they are on the wrong track. They are saying it's a >>> >>problem with their Underlying Carrier and that's what they are >>> >>attempting to debug. >>> >> >>> >>What I see is that Sipx sends an INVITE with SE of 600 (I reduced it >>> >>from the original 1800 to make it easier to debug). They send a 200 OK >>> >>with no SE header so no Session Timer will be in effect. And, they >>> claim >>> >>that they don't use Session Timers. Yet they send a BYE after 600 >>> >>seconds. I've tried different valuse: the original default of 1800, and >>> >>660 just to confirm it. They always send the BYE at the end of that >>> >>time. >>> >> >>> >>On Thu 14.Oct.10 23:51, Tony Graziano wrote: >>> >>>But why don't you have them setup the system and a test trunk of their >>> >>>own. >>> >>> >>> >>>That should be so much easier. >>> >>>============================ >>> >>>Tony Graziano, Manager >>> >>>Telephone: 434.984.8430 >>> >>>Fax: 434.984.8431 >>> >>> >>> >>>Email: [email protected] >>> >>> >>> >>>LAN/Telephony/Security and Control Systems Helpdesk: >>> >>>Telephone: 434.984.8426 >>> >>>Fax: 434.984.8427 >>> >>> >>> >>>Helpdesk Contract Customers: >>> >>>http://www.myitdepartment.net/gethelp/ >>> >>> >>> >>>----- Original Message ----- >>> >>>From: Tony Graziano <[email protected]> >>> >>>To: [email protected] <[email protected]> >>> >>>Sent: Thu Oct 14 18:10:30 2010 >>> >>>Subject: Re: [sipx-users] system configs >>> >>> >>> >>>You would have to send them a backup and theywould have everything. >>> >>> >>> >>>Pins, sip passwords, everything except root passwd. >>> >>> >>> >> >I would stay away from that. >>> >>>============================ >>> >>>Tony Graziano, Manager >>> >>>Telephone: 434.984.8430 >>> >>>Fax: 434.984.8431 >>> >>> >>> >>>Email: [email protected] >>> >>> >>> >>>LAN/Telephony/Security and Control Systems Helpdesk: >>> >>>Telephone: 434.984.8426 >>> >>>Fax: 434.984.8427 >>> >>> >>> >>>Helpdesk Contract Customers: >>> >>>http://www.myitdepartment.net/gethelp/ >>> >>> >>> >>>----- Original Message ----- >>> >>>From: [email protected] >>> >>><[email protected]> >>> >>>To: [email protected] <[email protected]> >>> >>>Sent: Thu Oct 14 17:00:13 2010 >>> >>>Subject: [sipx-users] system configs >>> >>> >>> >>>I'm still working with Flowroute on a dropped call problem. They have >>> >>>setup a SipX test system, but are not able to duplicate the problem. >>> >>>They would like me to send my configuration files so they can load >>> them >>> >>>into their system. >>> >>> >>> >>>1. Is this possible? What would I need to send, and is there a way to >>> >>>only include the config for the Flowroute gateway? >>> >>> >>> >>>2. What are the security/privacy worries with doing this? >>> >>> >>> >> >>> >>-- >>> >>Dan McDaniel >>> >>[email protected] >>> >>> _______________________________________________ >>> sipx-users mailing list >>> [email protected] >>> List Archive: http://list.sipfoundry.org/archive/sipx-users/ >>> >>> >> >> >> -- >> ====================== >> Tony Graziano, Manager >> Telephone: 434.984.8430 >> sip: [email protected] >> Fax: 434.326.5325 >> >> Email: [email protected] >> >> LAN/Telephony/Security and Control Systems Helpdesk: >> Telephone: 434.984.8426 >> sip: [email protected] >> >> Helpdesk Contract Customers: >> http://support.myitdepartment.net >> > > > > -- > Dan McDaniel > [email protected] > Key fingerprint = CAEC B8D9 3701 86CF D3B2 1E99 D8BB F217 455C AD36 > -- ====================== Tony Graziano, Manager Telephone: 434.984.8430 sip: [email protected] Fax: 434.326.5325 Email: [email protected] LAN/Telephony/Security and Control Systems Helpdesk: Telephone: 434.984.8426 sip: [email protected] Helpdesk Contract Customers: http://support.myitdepartment.net
_______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/
