There's no template for Flowroute. It's manual. I think I started with
the Vitelity template and modified it.

On Fri 15.Oct.10 06:01, Tony Graziano wrote:
>You might also consider totating the logs on sipx at the same time and do a
>merge-logs for a siptrace of the same period.
>
>I'm not at a system (phone), but is flowroute a trmplate or it is a manual
>gateway?
>============================
>Tony Graziano, Manager
>Telephone: 434.984.8430
>Fax: 434.984.8431
>
>Email: [email protected]
>
>LAN/Telephony/Security and Control Systems Helpdesk:
>Telephone: 434.984.8426
>Fax: 434.984.8427
>
>Helpdesk Contract Customers:
>http://www.myitdepartment.net/gethelp/
>
>----- Original Message -----
>From: Tony Graziano <[email protected]>
>To: [email protected] <[email protected]>
>Sent: Fri Oct 15 03:21:12 2010
>Subject: Re: [sipx-users] system configs
>
> I didn't know what firewall you are using. Pfsense will keep the state
>open, there in no setting needed.
>
>Their inhouse test is going through nat? And has a firewall? If not their
>test is flawed. Do a wan pcap to port 5060, full detail and specify their
>gateway address and run it beginning at 18 minutes into a call that drops
>in20. They should do the same.
>============================
>Tony Graziano, Manager
>Telephone: 434.984.8430
>Fax: 434.984.8431
>
>Email: [email protected]
>
>LAN/Telephony/Security and Control Systems Helpdesk:
>Telephone: 434.984.8426
>Fax: 434.984.8427
>
>Helpdesk Contract Customers:
>http://www.myitdepartment.net/gethelp/
>
>----- Original Message -----
>From: [email protected]
><[email protected]>
>To: [email protected] <[email protected]>
>Sent: Fri Oct 15 01:32:01 2010
>Subject: Re: [sipx-users] system configs
>
>I'm not familiar with that setting. Where is it found in pfSense?
>(Although this problem also occurs with a Vyatta firewall).
>
>And I'm a little confused as to how the firewall would know the value in
>the SE header. Can you elaborate?
>
>On Fri 15.Oct.10 00:59, Tony Graziano wrote:
>>Firewll has a ttl on your media nat session.
>>
>>What is it?
>>============================
>>Tony Graziano, Manager
>>Telephone: 434.984.8430
>>Fax: 434.984.8431
>>
>>Email: [email protected]
>>
>>LAN/Telephony/Security and Control Systems Helpdesk:
>>Telephone: 434.984.8426
>>Fax: 434.984.8427
>>
>>Helpdesk Contract Customers:
>>http://www.myitdepartment.net/gethelp/
>>
>>----- Original Message -----
>>From: [email protected]
>><[email protected]>
>>To: [email protected] <[email protected]>
>>Sent: Fri Oct 15 00:53:43 2010
>>Subject: Re: [sipx-users] system configs
>>
>>I think that's what they've done, but apparently the calls don't drop on
>>their system.
>>
>>Myself, I think they are on the wrong track. They are saying it's a
>>problem with their Underlying Carrier and that's what they are
>>attempting to debug.
>>
>>What I see is that Sipx sends an INVITE with SE of 600 (I reduced it
>>from the original 1800 to make it easier to debug). They send a 200 OK
>>with no SE header so no Session Timer will be in effect. And, they claim
>>that they don't use Session Timers. Yet they send a BYE after 600
>>seconds. I've tried different valuse: the original default of 1800, and
>>660 just to confirm it. They always send the BYE at the end of that
>>time.
>>
>>On Thu 14.Oct.10 23:51, Tony Graziano wrote:
>>>But why don't you have them setup the system and a test trunk of their
>>>own.
>>>
>>>That should be so much easier.
>>>============================
>>>Tony Graziano, Manager
>>>Telephone: 434.984.8430
>>>Fax: 434.984.8431
>>>
>>>Email: [email protected]
>>>
>>>LAN/Telephony/Security and Control Systems Helpdesk:
>>>Telephone: 434.984.8426
>>>Fax: 434.984.8427
>>>
>>>Helpdesk Contract Customers:
>>>http://www.myitdepartment.net/gethelp/
>>>
>>>----- Original Message -----
>>>From: Tony Graziano <[email protected]>
>>>To: [email protected] <[email protected]>
>>>Sent: Thu Oct 14 18:10:30 2010
>>>Subject: Re: [sipx-users] system configs
>>>
>>>You would have to send them a backup and theywould have everything.
>>>
>>>Pins, sip passwords,  everything except root passwd.
>>>
>>  >I would stay away from that.
>>>============================
>>>Tony Graziano, Manager
>>>Telephone: 434.984.8430
>>>Fax: 434.984.8431
>>>
>>>Email: [email protected]
>>>
>>>LAN/Telephony/Security and Control Systems Helpdesk:
>>>Telephone: 434.984.8426
>>>Fax: 434.984.8427
>>>
>>>Helpdesk Contract Customers:
>>>http://www.myitdepartment.net/gethelp/
>>>
>>>----- Original Message -----
>>>From: [email protected]
>>><[email protected]>
>>>To: [email protected] <[email protected]>
>>>Sent: Thu Oct 14 17:00:13 2010
>>>Subject: [sipx-users] system configs
>>>
>>>I'm still working with Flowroute on a dropped call problem. They have
>>>setup a SipX test system, but are not able to duplicate the problem.
>>>They would like me to send my configuration files so they can load them
>>>into their system.
>>>
>>>1. Is this possible? What would I need to send, and is there a way to
>>>only include the config for the Flowroute gateway?
>>>
>>>2. What are the security/privacy worries with doing this?
>>>
>>
>>--
>>Dan McDaniel
>>[email protected]