There's no template for Flowroute. It's manual. I think I started with the Vitelity template and modified it.
On Fri 15.Oct.10 06:01, Tony Graziano wrote: >You might also consider totating the logs on sipx at the same time and do a >merge-logs for a siptrace of the same period. > >I'm not at a system (phone), but is flowroute a trmplate or it is a manual >gateway? >============================ >Tony Graziano, Manager >Telephone: 434.984.8430 >Fax: 434.984.8431 > >Email: [email protected] > >LAN/Telephony/Security and Control Systems Helpdesk: >Telephone: 434.984.8426 >Fax: 434.984.8427 > >Helpdesk Contract Customers: >http://www.myitdepartment.net/gethelp/ > >----- Original Message ----- >From: Tony Graziano <[email protected]> >To: [email protected] <[email protected]> >Sent: Fri Oct 15 03:21:12 2010 >Subject: Re: [sipx-users] system configs > > I didn't know what firewall you are using. Pfsense will keep the state >open, there in no setting needed. > >Their inhouse test is going through nat? And has a firewall? If not their >test is flawed. Do a wan pcap to port 5060, full detail and specify their >gateway address and run it beginning at 18 minutes into a call that drops >in20. They should do the same. >============================ >Tony Graziano, Manager >Telephone: 434.984.8430 >Fax: 434.984.8431 > >Email: [email protected] > >LAN/Telephony/Security and Control Systems Helpdesk: >Telephone: 434.984.8426 >Fax: 434.984.8427 > >Helpdesk Contract Customers: >http://www.myitdepartment.net/gethelp/ > >----- Original Message ----- >From: [email protected] ><[email protected]> >To: [email protected] <[email protected]> >Sent: Fri Oct 15 01:32:01 2010 >Subject: Re: [sipx-users] system configs > >I'm not familiar with that setting. Where is it found in pfSense? >(Although this problem also occurs with a Vyatta firewall). > >And I'm a little confused as to how the firewall would know the value in >the SE header. Can you elaborate? > >On Fri 15.Oct.10 00:59, Tony Graziano wrote: >>Firewll has a ttl on your media nat session. >> >>What is it? >>============================ >>Tony Graziano, Manager >>Telephone: 434.984.8430 >>Fax: 434.984.8431 >> >>Email: [email protected] >> >>LAN/Telephony/Security and Control Systems Helpdesk: >>Telephone: 434.984.8426 >>Fax: 434.984.8427 >> >>Helpdesk Contract Customers: >>http://www.myitdepartment.net/gethelp/ >> >>----- Original Message ----- >>From: [email protected] >><[email protected]> >>To: [email protected] <[email protected]> >>Sent: Fri Oct 15 00:53:43 2010 >>Subject: Re: [sipx-users] system configs >> >>I think that's what they've done, but apparently the calls don't drop on >>their system. >> >>Myself, I think they are on the wrong track. They are saying it's a >>problem with their Underlying Carrier and that's what they are >>attempting to debug. >> >>What I see is that Sipx sends an INVITE with SE of 600 (I reduced it >>from the original 1800 to make it easier to debug). They send a 200 OK >>with no SE header so no Session Timer will be in effect. And, they claim >>that they don't use Session Timers. Yet they send a BYE after 600 >>seconds. I've tried different valuse: the original default of 1800, and >>660 just to confirm it. They always send the BYE at the end of that >>time. >> >>On Thu 14.Oct.10 23:51, Tony Graziano wrote: >>>But why don't you have them setup the system and a test trunk of their >>>own. >>> >>>That should be so much easier. >>>============================ >>>Tony Graziano, Manager >>>Telephone: 434.984.8430 >>>Fax: 434.984.8431 >>> >>>Email: [email protected] >>> >>>LAN/Telephony/Security and Control Systems Helpdesk: >>>Telephone: 434.984.8426 >>>Fax: 434.984.8427 >>> >>>Helpdesk Contract Customers: >>>http://www.myitdepartment.net/gethelp/ >>> >>>----- Original Message ----- >>>From: Tony Graziano <[email protected]> >>>To: [email protected] <[email protected]> >>>Sent: Thu Oct 14 18:10:30 2010 >>>Subject: Re: [sipx-users] system configs >>> >>>You would have to send them a backup and theywould have everything. >>> >>>Pins, sip passwords, everything except root passwd. >>> >> >I would stay away from that. >>>============================ >>>Tony Graziano, Manager >>>Telephone: 434.984.8430 >>>Fax: 434.984.8431 >>> >>>Email: [email protected] >>> >>>LAN/Telephony/Security and Control Systems Helpdesk: >>>Telephone: 434.984.8426 >>>Fax: 434.984.8427 >>> >>>Helpdesk Contract Customers: >>>http://www.myitdepartment.net/gethelp/ >>> >>>----- Original Message ----- >>>From: [email protected] >>><[email protected]> >>>To: [email protected] <[email protected]> >>>Sent: Thu Oct 14 17:00:13 2010 >>>Subject: [sipx-users] system configs >>> >>>I'm still working with Flowroute on a dropped call problem. They have >>>setup a SipX test system, but are not able to duplicate the problem. >>>They would like me to send my configuration files so they can load them >>>into their system. >>> >>>1. Is this possible? What would I need to send, and is there a way to >>>only include the config for the Flowroute gateway? >>> >>>2. What are the security/privacy worries with doing this? >>> >> >>-- >>Dan McDaniel >>[email protected] _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/
