Hi Mike,

there are several third-party replacements for the now unavailable IF-232C module that is needed on this and other early Kenwood rigs. Most faithfully replicate the original IF-232C, some may not. The manual is almost certainly correct, the reporter, if he is correct, almost certainly has a non-standard IF-232C replacement.

73
Bill
G4WJS.

On 08/02/2021 18:17, Black Michael via wsjt-devel wrote:
The dude said "manual is wrong".

Trying to get more information on serial cable to see if that's the cause.

Old thread noticed a difference between cable types on a 450.  Might have to do with RTS/CTS wiring differences and whether the cable supports hardware flow control.

https://wsprnet.org/drupal/node/1307 <https://wsprnet.org/drupal/node/1307>

Mike W9MDB


On Monday, February 8, 2021, 12:06:48 PM CST, Bill Somerville <[email protected]> wrote:


On 08/02/2021 17:45, Black Michael via wsjt-devel wrote:

> Anybody with a TS-450S out there that is available for some testing?
>
> I've got somebody claiming it needs 1 stop bit and XONXOFF handshake
> which I've never heard before and 2 stop bits and HARDWARE handshake
> is the default setup and has been for years.
>
> Mike W9MDB

Mike,


according to the TS-450S/TS-690S CAT programming manual it is full
duplex 4800 baud 8N2 with RTS/CTS flow control using TTL signal levels.
I would be very surprised if that information was incorrect!

73
Bill
G4WJS.