On 08/02/2021 20:00, Andy Stewart wrote:
On 2/7/21 7:00 PM, Barry Jackson wrote:
On 07/02/2021 17:04, Dr. Karsten Schmidt wrote:
Hi Barry,
yes I have a similar problem. A "2" in the GUI ist stored as "1" in the
config file.
-K
73 de dg1vs
Gentlemen,
Please do not edit the config file directly. Please use the GUI or you
will cause yourself problems, as you've noticed. How the data is stored
in the xlog.cfg file is of no consequence as long as xlog can read/write
it and behave correctly.
Through the GUI, I have seen no failure.
If you do things through the GUI and see a functional misbehavior,
please let me know the steps to reproduce it. When I tried it, there
was no problem with xlog 2.0.20 and hamlib4.
Thanks, and 73,
Andy
Hi Andy,
I finally got to the bottom of this. There were two serial port
parameters that are incorrect in hamlib for my radio, such that I have
always had to use the manual entry for stop_bits and handshake in most
applications.
Do the hamlib default settings overwrite the manual ones I wonder?
I finally corrected these in the hamlib sources and rebuilt our hamlib
package.
Without the manual settings being needed all works correctly as you
describe when using the rig selection dialogue.
I have sent the corrections upstream to hamlib, so while this fixes my
TS-450S issue it won't help Karsten.
Thanks for your help,
73
Barry