Chris Kennedy wrote:
I became aware of a problem in the cx25840 digitizer which we had
hit since changing the code from Ulfs original setup, where we would
reset the registers upon starting a capture. It seems if we don't
do this just right, then the chip doesn't setup itself to a good
state for things like the proc-amp and possibly other settings. I had
to figure out the best way to keep from losing other settings we manually
set but still give it this reset. So this attempts that, seems like it
should work, please test this if you've had problems with pvr150/500 cards
since the version 0.3.2u or so, and also if you are currently doing fine
with these cards, so we can make sure this is a good overall global solution
for everyone (and really the right thing to do). Video proc-amp settings
would be dark and red without these changes, and this could also be why
some don't have sound anymore and various other things (like no capture).
#0.3.3e: http://www.ivtv.tv/releases/ivtv-0.3/
Thanks,
Chris
Got a lot of "ENC IRQ OVERFLOW"
Sigurd
-------------------------------------------------------