Is the sync pipe working (what kind of sync pipe)?
The input from the sync pipe to the sync injector should have a light
that blinks once per second; likewise on the syncpipe.
If the syncpipe is working, the SiteMonitor will populate the satellite
data on the String I/O tab of the SiteMonitor (see below).
bp
<part15sbs{at}gmail{dot}com>
On 12/29/2015 4:18 PM, Scott Vander Dussen wrote:
Trying to use a SyncInjector to provide timing over power to a mix of
100/450APs.
Gigabit SyncInjector revision I0, SyncPipe Deluxe revision H1 both
receiving 27vdc. SyncPipe timing port directly to APs timing port
works fine. SyncPipe timing port to SyncInjector �SyncPipe or Daisy
Chain In� port does not seem to work. (see syncinjector.jpg) I�ve
tried two SyncInjectors with the same results. If the SyncInjector is
receiving sync from the SyncPipe, should I see the value column
populated? (See site monitor string.png)
Is there any configuration I need to change for the
SyncInjector/SiteMonitor to make this combo work? Thanks in advance.