Is the sync pipe working (what kind of sync pipe)?

The input from the sync pipe to the sync injector should have a light that blinks once per second; likewise on the syncpipe.

If the syncpipe is working, the SiteMonitor will populate the satellite data on the String I/O tab of the SiteMonitor (see below).

bp
<part15sbs{at}gmail{dot}com>


On 12/29/2015 4:18 PM, Scott Vander Dussen wrote:

Trying to use a SyncInjector to provide timing over power to a mix of 100/450APs.

Gigabit SyncInjector revision I0, SyncPipe Deluxe revision H1 both receiving 27vdc. SyncPipe timing port directly to APs timing port works fine. SyncPipe timing port to SyncInjector �SyncPipe or Daisy Chain In� port does not seem to work. (see syncinjector.jpg) I�ve tried two SyncInjectors with the same results. If the SyncInjector is receiving sync from the SyncPipe, should I see the value column populated? (See site monitor string.png)

Is there any configuration I need to change for the SyncInjector/SiteMonitor to make this combo work? Thanks in advance.


Reply via email to