When the syncpipe is plugged into the sync injector, it gets power and
transfers data over through the ethernet cable (RJ45 at each end).
bp
<part15sbs{at}gmail{dot}com>
On 12/29/2015 5:01 PM, Josh Luthman wrote:
No POE. Both devices need power. The Syncpipe has a GPS module and
does timing on the 6p6c ports.
Timing ports can be daisy chained (which is how SyncInjector gets timing).
Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
On Dec 29, 2015 7:53 PM, "Scott Vander Dussen" <[email protected]
<mailto:[email protected]>> wrote:
OK, so the SyncInjector provides PoE from its “SyncPipe or Daisy
Chain In” RJ45 port, and that plugs into the center RJ45 port of
the SyncPipe? So the SyncPipe receives PoE from the SyncInjector
and sends timing back though that same cable? I tried that and it
didn’t work :/
*From:*Af [mailto:[email protected]
<mailto:[email protected]>] *On Behalf Of *Josh Luthman
*Sent:* Tuesday, December 29, 2015 16:49
*To:* [email protected] <mailto:[email protected]>
*Subject:* Re: [AFMUG] SyncInjector n00b question
Correct. RJ45 simply won't fit on the outside ones.
It will have one of the LEDs on when it's powered/booted if memory
serves. Maybe green? I think the amber blinks every second or
three to let you know it's good to go...something like that...
Josh Luthman
Office: 937-552-2340 <tel:937-552-2340>
Direct: 937-552-2343 <tel:937-552-2343>
1100 Wayne St
Suite 1337
Troy, OH 45373
On Tue, Dec 29, 2015 at 7:46 PM, Steve Utick <[email protected]
<mailto:[email protected]>> wrote:
And, I believe it needs to be plugged into the center jack on
the SyncPipe as well, not the side ones. The side ones are
6p6c connectors to provide sync to a A/P by sync cable.
On Tue, Dec 29, 2015 at 5:44 PM, Josh Luthman
<[email protected]
<mailto:[email protected]>> wrote:
Syncpipe needs power. Up to 50v?
Josh Luthman
Office: 937-552-2340 <tel:937-552-2340>
Direct: 937-552-2343 <tel:937-552-2343>
1100 Wayne St
Suite 1337
Troy, OH 45373
On Dec 29, 2015 7:18 PM, "Scott Vander Dussen"
<[email protected] <mailto:[email protected]>> wrote:
Trying to use a SyncInjector to provide timing over
power to a mix of 100/450APs.
Gigabit SyncInjector revision I0, SyncPipe Deluxe
revision H1 both receiving 27vdc. SyncPipe timing port
directly to APs timing port works fine. SyncPipe
timing port to SyncInjector “SyncPipe or Daisy Chain
In” port does not seem to work. (see syncinjector.jpg)
I’ve tried two SyncInjectors with the same results.
If the SyncInjector is receiving sync from the
SyncPipe, should I see the value column populated?
(See site monitor string.png)
Is there any configuration I need to change for the
SyncInjector/SiteMonitor to make this combo work?
Thanks in advance.