On 23.01.16 17:08, andy pugh wrote:
> If you drill a hole of D-1p then you are at about 78% engagement.

That'll do me for M10 and up, but it's scary for Gene's M3.
I was certain I was going to break the tap if I persisted with 82%
engagement, which is as close to D-1p as you get with 0.1mm drill size
steps.

That's the thing with a simplistic rule of thumb, it breaks down at the
limits.

Erik

------------------------------------------------------------------------------