Hi Raoul,
With trunk on foundry and mode 4 on linux box with load balancing on l2
hash mode, load balance was happening is asymmetric way. IN traffic was
seen from one and OUT traffic was seen from another interface. I think
server mode on foundry might help but it seems we need to reload to
reconfigure it. Are there any way out for proper load balancing?
Regards,
--------
Rupesh Basnet
System Operations
Subisu Cablenet (P.) Ltd.
148 Thirbum Sadak
Baluwatar, Kathmandu
Nepal
T: 00977 1 4429616/17 Ext.: 322,323(4412832-Direct Line)
F: 00977 1 4430572
http://www.subisu.net.np
(An ISO 9001:2008 Certified Company)
On 03/30/2014 11:41 AM, Raoul Bhatia wrote:
On 30 March 2014 07:12:08 CEST, Rupesh Basnet <[email protected]> wrote:
Hi Erich,
I tried changing LACP rates with mode 4 but status was the same and
linux box was also not able to get partner MAC on its aggregation
status. I tried with balance-rr mode as well but same, only single MAC
was obtained under Load Balancing on foundry. I can pass traffic from
the bonded interface but still don't have any idea if those interfaces
are really bonded and load balance is happening.
Hi,
It has been some time since I was last configuring bonding but I *think* that
balancing happened on the basis of MAC addresses, (or even ports?) or some
other part of the packet header.
So while testing, you might see balancing only after using multiple streams and
source/destination MACs.
Cheers,
Raoul
_______________________________________________
foundry-nsp mailing list
[email protected]
http://puck.nether.net/mailman/listinfo/foundry-nsp