<https://lh3.googleusercontent.com/-Y-YUZng17Kg/Vz43wuCQSOI/AAAAAAAAAFM/XZa8wNkO8AwCxANqqVZU3sHQL_MLv-_gQCLcB/s1600/image1.JPG> Well, I went out and took another look at the control board today. and I found this. Looks burnt
On Thursday, May 19, 2016 at 2:46:13 PM UTC-5, Eric S wrote: > > no, but I might have to try that. > > On Thursday, May 19, 2016 at 1:26:15 PM UTC-5, bmacpiper wrote: >> >> Have you called Todd/WLL? He might have a way of testing the Giemme. I >> still think it might be covered if bad; six months is way too short for a >> life span on that part. >> >> Sent from my apple IIe >> >> On May 19, 2016, at 11:18, Eric S <[email protected]> wrote: >> >> The first relay with one large contact closes when the machine turns on, >> opens back up when the machine goes off, but I can't see anything happening >> with the second relay. >> >> On Thursday, May 19, 2016 at 12:47:30 PM UTC-5, bmacpiper wrote: >>> >>> Perhaps look through the blue clear box inside at the two relays--mine >>> had browned the plastic a bit but was barely noticeable. >>> b >>> >>> Sent from my apple IIe >>> >>> On May 19, 2016, at 10:43, Eric S <[email protected]> wrote: >>> >>> I took the cover off the giemme box this morning, and didn't see >>> anything obvious. I had a blown transformer on my last machine, but this >>> one doesn't look burnt like that one did. >>> >>> When I turn the machine on there is a click, but its in the AKO >>> controller, not the giemme box. Is that what you are talking about? >>> >>> On Thursday, May 19, 2016 at 11:39:14 AM UTC-5, Ira wrote: >>>> >>>> Hello Eric, >>>> >>>> Wednesday, May 18, 2016, 3:45:34 PM, you wrote: >>>> >>>> >>>> The pump works to fill the boilers, which I understand is its first >>>> job. but once the boilers are full it switches power to the pressure stat. >>>> to turn on the heaters. The white wire at the top of the pressure stat, >>>> I >>>> guess should be the power in. There is no power there. I chased that >>>> wire >>>> back to the terminal in the giemme box that says resistenza. >>>> >>>> >>>> Well, sounds like it's time to look inside the Gimme box and see if you >>>> can see something wrong. When you power the machine on, does the box click >>>> a bit later, few seconds max? If the box clicks, the pressurestat should >>>> get power. >>>> >>>> -- Ira >>>> >>> -- >>> You received this message because you are subscribed to the Google >>> Groups "Brewtus" group. >>> To unsubscribe from this group and stop receiving emails from it, send >>> an email to [email protected]. >>> To post to this group, send email to [email protected]. >>> Visit this group at https://groups.google.com/group/brewtus. >>> For more options, visit https://groups.google.com/d/optout. >>> >>> -- >> You received this message because you are subscribed to the Google Groups >> "Brewtus" group. >> To unsubscribe from this group and stop receiving emails from it, send an >> email to [email protected]. >> To post to this group, send email to [email protected]. >> Visit this group at https://groups.google.com/group/brewtus. >> For more options, visit https://groups.google.com/d/optout. >> >> -- You received this message because you are subscribed to the Google Groups "Brewtus" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To post to this group, send email to [email protected]. Visit this group at https://groups.google.com/group/brewtus. For more options, visit https://groups.google.com/d/optout.