This is our entry in CONSOLxx. I'm currently logged on to both members of the
sandbox sysplex.
CONSOLE DEVNUM(HMCS)
NAME(&SYSCLONE.HMCS)
AUTH(MASTER)
CMDSYS(*)
MSCOPE(*) /* PER HEALTH CHECKER */
ROUTCODE(1-10,12-16)
MONITOR(JOBNAMES-T)
.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-302-7535 Office
[email protected]
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf
Of Brian Westerman
Sent: Sunday, October 16, 2016 2:01 AM
To: [email protected]
Subject: (External):Re: HMCS consoles
When you ordered your z13, did it not come with at least one OSA-ICC adapter?
If it did, then you have (up to) 120 consoles that you can use at IPL for the
LPARs in your sysplex.
If you need help setting them up, send me an offline email and I can direct you
through it. It will take you all of about 10 minutes to do the OSA changes and
another 5 to generate the NIP OS consoles in your IODF.
Brian
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN