On 5 Sep 2007 at 17:23, auld.timer wrote:

> I've read a lot of messages about unconnected nets and most say the 
> trace is probably not connected to the center of the pin.  My problem 
> seems to be different.
> 
> I have no ERC errors, but I get a message on the through hole 
> components that the pads at x,y and x,y are not connected.  The x,y 
> coordinates are the same for both pads.  I interpret this to mean that 
> the top and bottom pads for the same hole are not connected. ie. the 
> hole is not plated.  Anybody know how to fix this?
> 
> Also, I have a problem connecting to internal planes.  I selected the 
> proper layers for the via's and then selected the proper working layer 
> and created/filled a zone.  It looks like there are connections, but 
> it still shows a ratsnest to the ground and power connections and I 
> have unconnected nets. I have deleted and gone through that process 
> twice.  
> 
> All help would be greatly appreciated.
  I had that problem and found I had accidently put 2 pads at the same 
location.  Try deleting the component or pad at that location and seeing if a 
2nd pad is there.  Delete it and re-place your component.

Dave - WB6DHW