brainerd,
Thanks, for the rapid reply. I didn't have time to work on it last night,
but I will tonight. I'll give that a try and let you know if it worked.
auld.timer
[EMAIL PROTECTED] wrote:
On 5 Sep 2007 at 17:23, auld.timer wrote:
> I've read a lot of messages about unconnected nets and most say the
> trace is probably not connected to the center of the pin. My problem
> seems to be different.
>
> I have no ERC errors, but I get a message on the through hole
> components that the pads at x,y and x,y are not connected. The x,y
> coordinates are the same for both pads. I interpret this to mean that
> the top and bottom pads for the same hole are not connected. ie. the
> hole is not plated. Anybody know how to fix this?
>
> Also, I have a problem connecting to internal planes. I selected the
> proper layers for the via's and then selected the proper working layer
> and created/filled a zone. It looks like there are connections, but
> it still shows a ratsnest to the ground and power connections and I
> have unconnected nets. I have deleted and gone through that process
> twice.
>
> All help would be greatly appreciated.
I had that problem and found I had accidently put 2 pads at the same
location. Try deleting the component or pad at that location and seeing if a
2nd pad is there. Delete it and re-place your component.
Dave - WB6DHW
<http://wb6dhw.com>
---------------------------------
Got a little couch potato?
Check out fun summer activities for kids.