Re: caught exception :Unable to get value of the property 'mObj'

2011-12-09 Thread Hamsagar, Ravindra
Could you please be bit specific like which IE version and which version of remedy you are using? We are using IE version 8 Onwards for AR 77 (Remedy) and it is working fine as of now. Thanks Ravindra From: Action Request System discussion list(ARSList) [mailto:arslist@ARSLIST.ORG] On Behalf

Re: caught exception :Unable to get value of the property 'mObj'

2011-12-09 Thread Ramagiri, Ravi Chandra
Hi Ravindra, We are using IE 8 and the version of Remedy is 7.6. Thanks and Regards RAVI CHANDRA R | Sr.BMC Remedy Administrator From: Action Request System discussion list(ARSList) [mailto:arslist@ARSLIST.ORG] On Behalf Of Hamsagar, Ravindra Sent: Friday, December 09, 2011 1:40

BMC IS HIRING - NORDICS AND RUSSIA

2011-12-09 Thread Asmar Ghafoor
Good day to everyone! Just wanted to give you an update that I am currently looking for ITSM Consultants in the Nordics. These are permanent opportunities, we are not looking for contractors or freelancers. I am running a recruitment day in Jan (in Stockholm or Copenhagen to be confirmed),

Re: Commit Changes vs PERFORM ACTION APPLY

2011-12-09 Thread Brittain, Mark
Thanks everyone for your responses. Personally I prefer to go with the Perform-Action-Apply when saving the current window. Maybe because it is newer. Mark From: Action Request System discussion list(ARSList) [mailto:arslist@ARSLIST.ORG] On Behalf Of Joe Martin D'Souza Sent: Thursday, December

Install 764 SP2 Question

2011-12-09 Thread Wilson, Bruce B
I am upgrading our ARSystem environment from 7.1.00 Patch 007 to 7.6.4 SP2. Do I begin by installing 7.6.4 first and then install 7.6.4 SP2 ...Or can I begin by installing 7.6.4 SP2 Thanks for the help, Bruce Wilson ___

Re: Install 764 SP2 Question

2011-12-09 Thread Walters, Mark
You can install SP2 directly. All of the patch/service pack installers are complete packages. Mark I work for BMC, I don't speak for them. From: Action Request System discussion list(ARSList) [mailto:arslist@ARSLIST.ORG] On Behalf Of Wilson, Bruce B Sent: 09 December 2011 13:24 To:

Re: BMC IS HIRING - NORDICS AND RUSSIA

2011-12-09 Thread Asmar Ghafoor
Please add me to Linked-in to see more opportunities in the respective geographies that you may live in: http://uk.linkedin.com/in/azzyg Also please request to join the BMC worldwide opportunities group on Linked-in, where you will see more of our global opps. Thanks. Asmar

5 year server sizing

2011-12-09 Thread Bennett, Craig
We are currently running ARS7.1 with older Change Asset applications on two servers (Windows 2003 32bit, Dell 2950 Dual Xeon 3Ghz, 4GB RAM) We are planning on installing 7.6.04 with ITSM and CMDB. I have requested a memory upgrade - but to do that we need an OS upgrade. Server group wants sizing

Re: 5 year server sizing

2011-12-09 Thread Erickson, David (INST Aqua Balance)
My understanding is outside a couple exceptions (PAE extensions, I believe) 32-bit OS' cannot see more than about 3 GB of RAM. So in your case a RAM upgrade without an OS upgrade would be a waste. I will also say we had a server 2003 setup with 7.6.04 with 4 GB of RAM and it screwed up badly

Re: 5 year server sizing

2011-12-09 Thread Bennett, Craig
Yes - was reminded of the 32bit 4GB limitation - server group offered us 2003 64bit or 2008sp2. I think we may go 2008sp2 - not sure if it will be real or virtual. Our QA environment is virtual (2003 64 bit) and seems to not have issues. Thanks -Original Message- From: Action Request

Re: caught exception :Unable to get value of the property 'mObj'

2011-12-09 Thread Chowdhury, Tauf
Ravi, This sometimes occurs (my opinion) when you needed to flush the mid tier cache or something during working hours when people were also actively using the system. So it could be some piece of corrupt data on the client side. The best thing to try initially is to clear your history and temp

Re: 5 year server sizing

2011-12-09 Thread Chowdhury, Tauf
For your mid tiers, I would look at some of the earlier posts on the list but basically, Mid Tier doesn't work properly if you try to use more than 1.4gb of RAM in Java. That may be something to consider when sizing those boxes. -Original Message- From: Action Request System discussion

BMC Data Management Load Tool 7.604p2

2011-12-09 Thread Terje Moglestue
From the Data Load Console I am trying to Convert CSV Files for the foundation data. Even the example data files generated by BMC generated run time errors, read-only errors and all shorts of things. Have anyone been able to use the Data Management Load Tool 7.604p2? I am asking about the

Flashboards - Observations

2011-12-09 Thread Axton
Environment Information: - ARS 7.5 patch 3 - Midtier 7.5 patch 3 I'm trying to use flashboards to render some data. I have 3 variables (fixed, floating write, floating read) that I am trying to plot using a stacked area chart over a time series (historical data). The data looks fine in a

BMC Aeroprise Mobility Suite

2011-12-09 Thread Warren R. Baltimore II
Does anyone know if the Mobility Suite (7.6.04) can be installed on a Virtual Windows Machine? I can't find a compatability matrix for the Aeroprise stuff and the installation guide only discusses actual hardware needs (Windows Servers). Thanks! -- Warren R. Baltimore II Remedy Developer

Re: BMC Aeroprise Mobility Suite

2011-12-09 Thread Easter, David
Hi Warren, In the absence of any product specific documentation, the general BMC Virtual Policy applies: Support Policy for Virtualized Platformshttp://www.bmc.com/support/policy-for-virtualized-platforms.html -David J. Easter Manager of Product Management, Remedy Platform BMC Software,

Re: BMC Aeroprise Mobility Suite

2011-12-09 Thread Tommy Morris
We are running on secured VM servers without issue. From: Action Request System discussion list(ARSList) [mailto:arslist@ARSLIST.ORG] On Behalf Of Warren R. Baltimore II Sent: Friday, December 09, 2011 11:44 AM To: arslist@ARSLIST.ORG Subject: BMC Aeroprise Mobility Suite ** Does anyone know if

Re: BMC Aeroprise Mobility Suite

2011-12-09 Thread Warren R. Baltimore II
Thanks Tommy, I guess my question was more about if it was supported! David sent me the answer though. I appreciate your help! On Fri, Dec 9, 2011 at 1:50 PM, Tommy Morris tommy.mor...@radioshack.comwrote: ** We are running on secured VM servers without issue. ** ** *From:* Action

Re: BMC Aeroprise Mobility Suite

2011-12-09 Thread Warren R. Baltimore II
Thanks David! On Fri, Dec 9, 2011 at 1:20 PM, Easter, David david_eas...@bmc.com wrote: ** Hi Warren, ** ** In the absence of any product specific documentation, the general BMC Virtual Policy applies: ** ** Support Policy for Virtualized

Re: SRM Issue

2011-12-09 Thread John Sundberg
(ADV: Recommends looking at Kinetic Request if SRM becomes problematic) Generically speaking - I would take off Quantity as a question -- it does not make sense. All questions should be relevant - else -- you are confusing people. I mean - am I supposed to put a number in there? -- Does it auto

Re: 5 year server sizing

2011-12-09 Thread Nathan Aker
I would recommend using the 7.6.00 reference architecture specifications (they provide 3 models based on a small, medium, large deployment) and in my experience so far I would add 15%-20% to the recommended midtier specs for 7.6.04. Just my opinion. Nate. Nathan Aker ITSM Solution Architect

Incident Management - building reports

2011-12-09 Thread Christine Milton Hall
Hi everyone - Hoping someone can help me out... I am the functional person for our environment, not technical.. I have currently created some requirements for reporting (to a spreadsheet). We have a couple of options for tools. Crystal reporting (out of Remedy), Remedy AR, and BMC Analytics.

Re: Incident Management - building reports

2011-12-09 Thread Nathan Aker
Options in terms of preference (according to my personal opinion): 1. Analytics – allows non-technical users to build reports and extract the data like you indicate below as well as do all your own formatting and editing and build the report without having to understand the DB data model

Re: Incident Management - building reports

2011-12-09 Thread Andrew C Goodall
We use Microsoft SQL Reporting Services (SSRS) for our analytical needs; obviously we have a SQL Server DB. We added a SQL snapshot for reporting purposes of the live ARSystem DB to make sure we were only hitting the live db for reporting purposes when absolutely necessary, e.g. when needing to

BMC Analytics

2011-12-09 Thread Christine Milton Hall
Hi everyone... Sorry to bug you all again... Does anyone know where I can get training for Analytics? thanks! c ** This e-mail and any files transmitted with it may contain confidential information and is intended solely for

Re: BMC Analytics

2011-12-09 Thread Rick Cook
Rapid Technologies has BA training classes. Rick On Dec 9, 2011 4:58 PM, Christine Milton Hall christine_milton_h...@pepperidgefarm.com wrote: ** Hi everyone... Sorry to bug you all again... Does anyone know where I can get training for Analytics? thanks! c

Re: BMC Analytics

2011-12-09 Thread Chowdhury, Tauf
Christine, Analytics really isn't a Remedy module. It's basically a custom universe created by BMC based on the Remedy data model on the Business Objects platform. So I think the training that would be helpful is to first understand how Remedy data is structured within the DB. For example,

Re: BMC Analytics

2011-12-09 Thread Chowdhury, Tauf
Ehh, I like Rick's answer better. I just babbled on for no reason :P From: Action Request System discussion list(ARSList) [mailto:arslist@ARSLIST.ORG] On Behalf Of Rick Cook Sent: Friday, December 09, 2011 5:00 PM To: arslist@ARSLIST.ORG Subject: Re: BMC Analytics ** Rapid Technologies

Re: capture midtier qualification to be used to create a URL with mode=searchqual=?

2011-12-09 Thread Andrew C Goodall
Not sure if this helps. Examples below - these are for SSRS report links but you can use the same approach with some changes to the syntax and criteria for the qual line reference. I'm sure you could use same approach on a field and use workflow to auto build the qual line. FYI - important to

Re: BMC Analytics

2011-12-09 Thread Pat Zandi
Just read the manuals::: Sent from my iPhone On Dec 9, 2011, at 17:00, Rick Cook remedyr...@gmail.com wrote: ** Rapid Technologies has BA training classes. Rick On Dec 9, 2011 4:58 PM, Christine Milton Hall christine_milton_h...@pepperidgefarm.com wrote: ** Hi everyone... Sorry

Re: BMC Data Management Load Tool 7.604p2

2011-12-09 Thread SUBSCRIBE h@rry
Terje, I am currently using the Data Management tool 7.6.04 p2 for uploading data, i had some problems initially using the 'Convert CSV' option, strange as it seems, data was not converting into csv files if the source excel file was in a folder (D drive) other than the data management install