I would use the 48VH (assuming we're still talking about the 450i AP) power
on all 4 pairs is what they want, and they don't care about polarity.

On Tue, Aug 16, 2016 at 6:47 PM, Josh Luthman <[email protected]>
wrote:

> I know the H has power on all pins so I'd suggest looking in the forum
> before plugging it in.
>
> Josh Luthman
> Office: 937-552-2340
> Direct: 937-552-2343
> 1100 Wayne St
> Suite 1337
> Troy, OH 45373
>
> On Aug 16, 2016 7:40 PM, "Darin Steffl" <[email protected]> wrote:
>
>> So should I use regular 48V (0.75A) or 48VH (1.5A) for Netonix powering
>> 450i AP 900mhz?
>>
>>
>>
>> On Tue, Aug 16, 2016 at 5:43 PM, CBB - Jay Fuller <
>> [email protected]> wrote:
>>
>>>
>>> i keep trying to preach that.
>>> i know we have one site with two sync sources
>>> no apparent problems tho
>>>
>>>
>>> ----- Original Message -----
>>> *From:* Josh Luthman <[email protected]>
>>> *To:* [email protected]
>>> *Sent:* Tuesday, August 16, 2016 4:23 PM
>>> *Subject:* Re: [AFMUG] PMP450i 900mhz and Netonix
>>>
>>> It's proper to have one sync source at the site anyway.
>>>
>>> Josh Luthman
>>> Office: 937-552-2340
>>> Direct: 937-552-2343
>>> 1100 Wayne St
>>> Suite 1337
>>> Troy, OH 45373
>>>
>>> On Aug 16, 2016 5:14 PM, "Kurt Fankhauser" <[email protected]>
>>> wrote:
>>>
>>>> it would be better if it (450i) had on-board sync so i can power the
>>>> whole tower with one Netonix Switch and be done, but no i gotta mess around
>>>> with a CTM2 or Packet Flux Sync Injector now to get timing on 450i
>>>>
>>>> On Tue, Aug 16, 2016 at 3:23 PM, George Skorup <[email protected]>
>>>> wrote:
>>>>
>>>>> As others have said, you obviously won't get sync from the Netonix.
>>>>> Plug the 450i *AP* in and go. It is 802.3at compliant, but it will also
>>>>> take passive injected power without issue. And you don't need to change 
>>>>> any
>>>>> wires around. It will take either polarity on any pair. Cambium actually
>>>>> did this right. Woulda been even better if they designed for 20-60vdc, but
>>>>> I guess you can never have it all.
>>>>>
>>>>> Out of the 450i series, the only radio that is not 802.3at is the 900
>>>>> SM which is the old Canopy 29.5v like FSK and regular 450.
>>>>>
>>>>> On 8/16/2016 12:18 PM, Darin Steffl wrote:
>>>>>
>>>>> Hello all,
>>>>>
>>>>> Will a Netonix 48V switch power the PMP450i 900mhz?
>>>>>
>>>>> I'm leaning towards that it will NOT due to needing 48-56V and 802.3at
>>>>> PoE which I don't think Netonix supports.
>>>>>
>>>>> Can anyone confirm my thoughts or tell me I'm wrong and it will work?
>>>>>
>>>>> Thanks
>>>>>
>>>>> --
>>>>> Darin Steffl
>>>>> Minnesota WiFi
>>>>> www.mnwifi.com
>>>>> 507-634-WiFi
>>>>> <http://www.facebook.com/minnesotawifi> Like us on Facebook
>>>>> <http://www.facebook.com/minnesotawifi>
>>>>>
>>>>>
>>>>>
>>>>
>>
>>
>> --
>> Darin Steffl
>> Minnesota WiFi
>> www.mnwifi.com
>> 507-634-WiFi
>> <http://www.facebook.com/minnesotawifi> Like us on Facebook
>> <http://www.facebook.com/minnesotawifi>
>>
>

Reply via email to