I would use the 48VH (assuming we're still talking about the 450i AP) power on all 4 pairs is what they want, and they don't care about polarity.
On Tue, Aug 16, 2016 at 6:47 PM, Josh Luthman <[email protected]> wrote: > I know the H has power on all pins so I'd suggest looking in the forum > before plugging it in. > > Josh Luthman > Office: 937-552-2340 > Direct: 937-552-2343 > 1100 Wayne St > Suite 1337 > Troy, OH 45373 > > On Aug 16, 2016 7:40 PM, "Darin Steffl" <[email protected]> wrote: > >> So should I use regular 48V (0.75A) or 48VH (1.5A) for Netonix powering >> 450i AP 900mhz? >> >> >> >> On Tue, Aug 16, 2016 at 5:43 PM, CBB - Jay Fuller < >> [email protected]> wrote: >> >>> >>> i keep trying to preach that. >>> i know we have one site with two sync sources >>> no apparent problems tho >>> >>> >>> ----- Original Message ----- >>> *From:* Josh Luthman <[email protected]> >>> *To:* [email protected] >>> *Sent:* Tuesday, August 16, 2016 4:23 PM >>> *Subject:* Re: [AFMUG] PMP450i 900mhz and Netonix >>> >>> It's proper to have one sync source at the site anyway. >>> >>> Josh Luthman >>> Office: 937-552-2340 >>> Direct: 937-552-2343 >>> 1100 Wayne St >>> Suite 1337 >>> Troy, OH 45373 >>> >>> On Aug 16, 2016 5:14 PM, "Kurt Fankhauser" <[email protected]> >>> wrote: >>> >>>> it would be better if it (450i) had on-board sync so i can power the >>>> whole tower with one Netonix Switch and be done, but no i gotta mess around >>>> with a CTM2 or Packet Flux Sync Injector now to get timing on 450i >>>> >>>> On Tue, Aug 16, 2016 at 3:23 PM, George Skorup <[email protected]> >>>> wrote: >>>> >>>>> As others have said, you obviously won't get sync from the Netonix. >>>>> Plug the 450i *AP* in and go. It is 802.3at compliant, but it will also >>>>> take passive injected power without issue. And you don't need to change >>>>> any >>>>> wires around. It will take either polarity on any pair. Cambium actually >>>>> did this right. Woulda been even better if they designed for 20-60vdc, but >>>>> I guess you can never have it all. >>>>> >>>>> Out of the 450i series, the only radio that is not 802.3at is the 900 >>>>> SM which is the old Canopy 29.5v like FSK and regular 450. >>>>> >>>>> On 8/16/2016 12:18 PM, Darin Steffl wrote: >>>>> >>>>> Hello all, >>>>> >>>>> Will a Netonix 48V switch power the PMP450i 900mhz? >>>>> >>>>> I'm leaning towards that it will NOT due to needing 48-56V and 802.3at >>>>> PoE which I don't think Netonix supports. >>>>> >>>>> Can anyone confirm my thoughts or tell me I'm wrong and it will work? >>>>> >>>>> Thanks >>>>> >>>>> -- >>>>> Darin Steffl >>>>> Minnesota WiFi >>>>> www.mnwifi.com >>>>> 507-634-WiFi >>>>> <http://www.facebook.com/minnesotawifi> Like us on Facebook >>>>> <http://www.facebook.com/minnesotawifi> >>>>> >>>>> >>>>> >>>> >> >> >> -- >> Darin Steffl >> Minnesota WiFi >> www.mnwifi.com >> 507-634-WiFi >> <http://www.facebook.com/minnesotawifi> Like us on Facebook >> <http://www.facebook.com/minnesotawifi> >> >