so the 24v radios will still link their ethernet at gigabit after you switch the brown/blue wires?
On Tue, Aug 16, 2016 at 2:03 PM, Christopher Tyler <[email protected] > wrote: > The SM's are still reversed and use the 30c Cambium power supply, but the > AP's are not. > > -- > Christopher Tyler > MTCRE/MTCNA/MTCTCE/MTCWE > Total Highspeed Internet Services > 417.851.1107 > > ----- Original Message ----- > From: "Christopher Tyler" <[email protected]> > To: [email protected] > Sent: Tuesday, August 16, 2016 1:01:55 PM > Subject: Re: [AFMUG] PMP450i 900mhz and Netonix > > The 450i AP's use standard PoE. It's not reversed. > > -- > Christopher Tyler > MTCRE/MTCNA/MTCTCE/MTCWE > Total Highspeed Internet Services > 417.851.1107 > > ----- Original Message ----- > From: "Josh Luthman" <[email protected]> > To: [email protected] > Sent: Tuesday, August 16, 2016 1:00:48 PM > Subject: Re: [AFMUG] PMP450i 900mhz and Netonix > > Change the pinout I believe. > > > Josh Luthman > Office: 937-552-2340 > Direct: 937-552-2343 > 1100 Wayne St > Suite 1337 > Troy, OH 45373 > > On Tue, Aug 16, 2016 at 1:59 PM, Kurt Fankhauser <[email protected] > > > wrote: > > > how do you do gigabit with the 24v polarity needing reversed? > > > > On Tue, Aug 16, 2016 at 1:57 PM, Josh Luthman < > [email protected] > > > wrote: > > > >> 24v and 48v but Netonix does both > >> > >> > >> Josh Luthman > >> Office: 937-552-2340 > >> Direct: 937-552-2343 > >> 1100 Wayne St > >> Suite 1337 > >> Troy, OH 45373 > >> > >> On Tue, Aug 16, 2016 at 1:48 PM, Kurt Fankhauser < > >> [email protected]> wrote: > >> > >>> pmp450 and pmp450i have different poe voltages > >>> > >>> On Tue, Aug 16, 2016 at 1:31 PM, Craig House <[email protected] > > > >>> wrote: > >>> > >>>> It will work we're using it in many places > >>>> > >>>> Sent from my iPhone > >>>> > >>>> On Aug 16, 2016, at 12:30, Bill Prince <[email protected]> wrote: > >>>> > >>>> It will probably power it, but it won't provide sync. > >>>> > >>>> > >>>> bp > >>>> <part15sbs{at}gmail{dot}com> > >>>> > >>>> > >>>> On 8/16/2016 10:18 AM, Darin Steffl wrote: > >>>> > >>>> Hello all, > >>>> > >>>> Will a Netonix 48V switch power the PMP450i 900mhz? > >>>> > >>>> I'm leaning towards that it will NOT due to needing 48-56V and 802.3at > >>>> PoE which I don't think Netonix supports. > >>>> > >>>> Can anyone confirm my thoughts or tell me I'm wrong and it will work? > >>>> > >>>> Thanks > >>>> > >>>> -- > >>>> Darin Steffl > >>>> Minnesota WiFi > >>>> www.mnwifi.com > >>>> 507-634-WiFi > >>>> <http://www.facebook.com/minnesotawifi> Like us on Facebook > >>>> <http://www.facebook.com/minnesotawifi> > >>>> > >>>> > >>>> > >>> > >> > > >