Sorry got a bit confused with the 450/450i discussion.Josh is correct, the 450 
AP is reversed the 450i AP is not.

-- 
Christopher Tyler 
MTCRE/MTCNA/MTCTCE/MTCWE 
Total Highspeed Internet Services 
417.851.1107

----- Original Message -----
From: "Christopher Tyler" <ch...@totalhighspeed.net>
To: af@afmug.com
Sent: Tuesday, August 16, 2016 1:11:11 PM
Subject: Re: [AFMUG] PMP450i 900mhz and Netonix

No, the 450i AP uses normal PoE. The SM/CPE requires a pin swap.

"Access point is now 802.3at compatible and includes an AUX port, while the 
Subscriber can re-use the 30 VDC power supplies common to the PMP 100 platform"

-- 
Christopher Tyler 
MTCRE/MTCNA/MTCTCE/MTCWE 
Total Highspeed Internet Services 
417.851.1107

----- Original Message -----
From: "Josh Luthman" <j...@imaginenetworksllc.com>
To: af@afmug.com
Sent: Tuesday, August 16, 2016 1:05:36 PM
Subject: Re: [AFMUG] PMP450i 900mhz and Netonix

450, not 450i


Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373

On Tue, Aug 16, 2016 at 2:01 PM, Christopher Tyler <ch...@totalhighspeed.net
> wrote:

> The 450i AP's use standard PoE. It's not reversed.
>
> --
> Christopher Tyler
> MTCRE/MTCNA/MTCTCE/MTCWE
> Total Highspeed Internet Services
> 417.851.1107
>
> ----- Original Message -----
> From: "Josh Luthman" <j...@imaginenetworksllc.com>
> To: af@afmug.com
> Sent: Tuesday, August 16, 2016 1:00:48 PM
> Subject: Re: [AFMUG] PMP450i 900mhz and Netonix
>
> Change the pinout I believe.
>
>
> Josh Luthman
> Office: 937-552-2340
> Direct: 937-552-2343
> 1100 Wayne St
> Suite 1337
> Troy, OH 45373
>
> On Tue, Aug 16, 2016 at 1:59 PM, Kurt Fankhauser <lists.wavel...@gmail.com
> >
> wrote:
>
> > how do you do gigabit with the 24v polarity needing reversed?
> >
> > On Tue, Aug 16, 2016 at 1:57 PM, Josh Luthman <
> j...@imaginenetworksllc.com
> > > wrote:
> >
> >> 24v and 48v but Netonix does both
> >>
> >>
> >> Josh Luthman
> >> Office: 937-552-2340
> >> Direct: 937-552-2343
> >> 1100 Wayne St
> >> Suite 1337
> >> Troy, OH 45373
> >>
> >> On Tue, Aug 16, 2016 at 1:48 PM, Kurt Fankhauser <
> >> lists.wavel...@gmail.com> wrote:
> >>
> >>> pmp450 and pmp450i have different poe voltages
> >>>
> >>> On Tue, Aug 16, 2016 at 1:31 PM, Craig House <cr...@totalhighspeed.net
> >
> >>> wrote:
> >>>
> >>>> It will work we're using it in many places
> >>>>
> >>>> Sent from my iPhone
> >>>>
> >>>> On Aug 16, 2016, at 12:30, Bill Prince <part15...@gmail.com> wrote:
> >>>>
> >>>> It will probably power it, but it won't provide sync.
> >>>>
> >>>>
> >>>> bp
> >>>> <part15sbs{at}gmail{dot}com>
> >>>>
> >>>>
> >>>> On 8/16/2016 10:18 AM, Darin Steffl wrote:
> >>>>
> >>>> Hello all,
> >>>>
> >>>> Will a Netonix 48V switch power the PMP450i 900mhz?
> >>>>
> >>>> I'm leaning towards that it will NOT due to needing 48-56V and 802.3at
> >>>> PoE which I don't think Netonix supports.
> >>>>
> >>>> Can anyone confirm my thoughts or tell me I'm wrong and it will work?
> >>>>
> >>>> Thanks
> >>>>
> >>>> --
> >>>> Darin Steffl
> >>>> Minnesota WiFi
> >>>> www.mnwifi.com
> >>>> 507-634-WiFi
> >>>> <http://www.facebook.com/minnesotawifi> Like us on Facebook
> >>>> <http://www.facebook.com/minnesotawifi>
> >>>>
> >>>>
> >>>>
> >>>
> >>
> >
>

Reply via email to