I know the H has power on all pins so I'd suggest looking in the forum
before plugging it in.

Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373

On Aug 16, 2016 7:40 PM, "Darin Steffl" <[email protected]> wrote:

> So should I use regular 48V (0.75A) or 48VH (1.5A) for Netonix powering
> 450i AP 900mhz?
>
>
>
> On Tue, Aug 16, 2016 at 5:43 PM, CBB - Jay Fuller <
> [email protected]> wrote:
>
>>
>> i keep trying to preach that.
>> i know we have one site with two sync sources
>> no apparent problems tho
>>
>>
>> ----- Original Message -----
>> *From:* Josh Luthman <[email protected]>
>> *To:* [email protected]
>> *Sent:* Tuesday, August 16, 2016 4:23 PM
>> *Subject:* Re: [AFMUG] PMP450i 900mhz and Netonix
>>
>> It's proper to have one sync source at the site anyway.
>>
>> Josh Luthman
>> Office: 937-552-2340
>> Direct: 937-552-2343
>> 1100 Wayne St
>> Suite 1337
>> Troy, OH 45373
>>
>> On Aug 16, 2016 5:14 PM, "Kurt Fankhauser" <[email protected]>
>> wrote:
>>
>>> it would be better if it (450i) had on-board sync so i can power the
>>> whole tower with one Netonix Switch and be done, but no i gotta mess around
>>> with a CTM2 or Packet Flux Sync Injector now to get timing on 450i
>>>
>>> On Tue, Aug 16, 2016 at 3:23 PM, George Skorup <[email protected]>
>>> wrote:
>>>
>>>> As others have said, you obviously won't get sync from the Netonix.
>>>> Plug the 450i *AP* in and go. It is 802.3at compliant, but it will also
>>>> take passive injected power without issue. And you don't need to change any
>>>> wires around. It will take either polarity on any pair. Cambium actually
>>>> did this right. Woulda been even better if they designed for 20-60vdc, but
>>>> I guess you can never have it all.
>>>>
>>>> Out of the 450i series, the only radio that is not 802.3at is the 900
>>>> SM which is the old Canopy 29.5v like FSK and regular 450.
>>>>
>>>> On 8/16/2016 12:18 PM, Darin Steffl wrote:
>>>>
>>>> Hello all,
>>>>
>>>> Will a Netonix 48V switch power the PMP450i 900mhz?
>>>>
>>>> I'm leaning towards that it will NOT due to needing 48-56V and 802.3at
>>>> PoE which I don't think Netonix supports.
>>>>
>>>> Can anyone confirm my thoughts or tell me I'm wrong and it will work?
>>>>
>>>> Thanks
>>>>
>>>> --
>>>> Darin Steffl
>>>> Minnesota WiFi
>>>> www.mnwifi.com
>>>> 507-634-WiFi
>>>> <http://www.facebook.com/minnesotawifi> Like us on Facebook
>>>> <http://www.facebook.com/minnesotawifi>
>>>>
>>>>
>>>>
>>>
>
>
> --
> Darin Steffl
> Minnesota WiFi
> www.mnwifi.com
> 507-634-WiFi
> <http://www.facebook.com/minnesotawifi> Like us on Facebook
> <http://www.facebook.com/minnesotawifi>
>

Reply via email to