I know the H has power on all pins so I'd suggest looking in the forum before plugging it in.
Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Aug 16, 2016 7:40 PM, "Darin Steffl" <[email protected]> wrote: > So should I use regular 48V (0.75A) or 48VH (1.5A) for Netonix powering > 450i AP 900mhz? > > > > On Tue, Aug 16, 2016 at 5:43 PM, CBB - Jay Fuller < > [email protected]> wrote: > >> >> i keep trying to preach that. >> i know we have one site with two sync sources >> no apparent problems tho >> >> >> ----- Original Message ----- >> *From:* Josh Luthman <[email protected]> >> *To:* [email protected] >> *Sent:* Tuesday, August 16, 2016 4:23 PM >> *Subject:* Re: [AFMUG] PMP450i 900mhz and Netonix >> >> It's proper to have one sync source at the site anyway. >> >> Josh Luthman >> Office: 937-552-2340 >> Direct: 937-552-2343 >> 1100 Wayne St >> Suite 1337 >> Troy, OH 45373 >> >> On Aug 16, 2016 5:14 PM, "Kurt Fankhauser" <[email protected]> >> wrote: >> >>> it would be better if it (450i) had on-board sync so i can power the >>> whole tower with one Netonix Switch and be done, but no i gotta mess around >>> with a CTM2 or Packet Flux Sync Injector now to get timing on 450i >>> >>> On Tue, Aug 16, 2016 at 3:23 PM, George Skorup <[email protected]> >>> wrote: >>> >>>> As others have said, you obviously won't get sync from the Netonix. >>>> Plug the 450i *AP* in and go. It is 802.3at compliant, but it will also >>>> take passive injected power without issue. And you don't need to change any >>>> wires around. It will take either polarity on any pair. Cambium actually >>>> did this right. Woulda been even better if they designed for 20-60vdc, but >>>> I guess you can never have it all. >>>> >>>> Out of the 450i series, the only radio that is not 802.3at is the 900 >>>> SM which is the old Canopy 29.5v like FSK and regular 450. >>>> >>>> On 8/16/2016 12:18 PM, Darin Steffl wrote: >>>> >>>> Hello all, >>>> >>>> Will a Netonix 48V switch power the PMP450i 900mhz? >>>> >>>> I'm leaning towards that it will NOT due to needing 48-56V and 802.3at >>>> PoE which I don't think Netonix supports. >>>> >>>> Can anyone confirm my thoughts or tell me I'm wrong and it will work? >>>> >>>> Thanks >>>> >>>> -- >>>> Darin Steffl >>>> Minnesota WiFi >>>> www.mnwifi.com >>>> 507-634-WiFi >>>> <http://www.facebook.com/minnesotawifi> Like us on Facebook >>>> <http://www.facebook.com/minnesotawifi> >>>> >>>> >>>> >>> > > > -- > Darin Steffl > Minnesota WiFi > www.mnwifi.com > 507-634-WiFi > <http://www.facebook.com/minnesotawifi> Like us on Facebook > <http://www.facebook.com/minnesotawifi> >