As others have said, you obviously won't get sync from the Netonix. Plug the 450i *AP* in and go. It is 802.3at compliant, but it will also take passive injected power without issue. And you don't need to change any wires around. It will take either polarity on any pair. Cambium actually did this right. Woulda been even better if they designed for 20-60vdc, but I guess you can never have it all.

Out of the 450i series, the only radio that is not 802.3at is the 900 SM which is the old Canopy 29.5v like FSK and regular 450.

On 8/16/2016 12:18 PM, Darin Steffl wrote:
Hello all,

Will a Netonix 48V switch power the PMP450i 900mhz?

I'm leaning towards that it will NOT due to needing 48-56V and 802.3at PoE which I don't think Netonix supports.

Can anyone confirm my thoughts or tell me I'm wrong and it will work?

Thanks

--
Darin Steffl
Minnesota WiFi
www.mnwifi.com <http://www.mnwifi.com/>
507-634-WiFi
<http://www.facebook.com/minnesotawifi> Like us on Facebook <http://www.facebook.com/minnesotawifi>