i keep trying to preach that. i know we have one site with two sync sources no apparent problems tho
----- Original Message ----- From: Josh Luthman To: [email protected] Sent: Tuesday, August 16, 2016 4:23 PM Subject: Re: [AFMUG] PMP450i 900mhz and Netonix It's proper to have one sync source at the site anyway. Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Aug 16, 2016 5:14 PM, "Kurt Fankhauser" <[email protected]> wrote: it would be better if it (450i) had on-board sync so i can power the whole tower with one Netonix Switch and be done, but no i gotta mess around with a CTM2 or Packet Flux Sync Injector now to get timing on 450i On Tue, Aug 16, 2016 at 3:23 PM, George Skorup <[email protected]> wrote: As others have said, you obviously won't get sync from the Netonix. Plug the 450i *AP* in and go. It is 802.3at compliant, but it will also take passive injected power without issue. And you don't need to change any wires around. It will take either polarity on any pair. Cambium actually did this right. Woulda been even better if they designed for 20-60vdc, but I guess you can never have it all. Out of the 450i series, the only radio that is not 802.3at is the 900 SM which is the old Canopy 29.5v like FSK and regular 450. On 8/16/2016 12:18 PM, Darin Steffl wrote: Hello all, Will a Netonix 48V switch power the PMP450i 900mhz? I'm leaning towards that it will NOT due to needing 48-56V and 802.3at PoE which I don't think Netonix supports. Can anyone confirm my thoughts or tell me I'm wrong and it will work? Thanks -- Darin Steffl Minnesota WiFi www.mnwifi.com 507-634-WiFi Like us on Facebook