It's proper to have one sync source at the site anyway. Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373
On Aug 16, 2016 5:14 PM, "Kurt Fankhauser" <[email protected]> wrote: > it would be better if it (450i) had on-board sync so i can power the whole > tower with one Netonix Switch and be done, but no i gotta mess around with > a CTM2 or Packet Flux Sync Injector now to get timing on 450i > > On Tue, Aug 16, 2016 at 3:23 PM, George Skorup <[email protected]> wrote: > >> As others have said, you obviously won't get sync from the Netonix. Plug >> the 450i *AP* in and go. It is 802.3at compliant, but it will also take >> passive injected power without issue. And you don't need to change any >> wires around. It will take either polarity on any pair. Cambium actually >> did this right. Woulda been even better if they designed for 20-60vdc, but >> I guess you can never have it all. >> >> Out of the 450i series, the only radio that is not 802.3at is the 900 SM >> which is the old Canopy 29.5v like FSK and regular 450. >> >> On 8/16/2016 12:18 PM, Darin Steffl wrote: >> >> Hello all, >> >> Will a Netonix 48V switch power the PMP450i 900mhz? >> >> I'm leaning towards that it will NOT due to needing 48-56V and 802.3at >> PoE which I don't think Netonix supports. >> >> Can anyone confirm my thoughts or tell me I'm wrong and it will work? >> >> Thanks >> >> -- >> Darin Steffl >> Minnesota WiFi >> www.mnwifi.com >> 507-634-WiFi >> <http://www.facebook.com/minnesotawifi> Like us on Facebook >> <http://www.facebook.com/minnesotawifi> >> >> >> >