At 10:38 AM 7/15/2009, you wrote:
>Hmm, it's closer to 5 seconds, maybe 10 at most.  The pressure looks 
>good when I start steaming though (about 1.5 bars).
>
>I should also mention that a few months ago it was looking like my 
>pressurestat was acting up.  The pressure would climb into the red 
>and the safety thingy would start releasing steam in an impressive 
>display of hissing, then it would recover. It did this several times 
>a day.  I was going to order a pressurestat, but then it stopped 
>having its hissy fits and returned to normal.  Related?

Have you ever de-scaled it. 5 or 10 seconds of cold water shouldn't 
be able to kill the steam pressure.  Can you just watch it drop when 
the pump starts pumping? If you turn off the machine so the pump does 
not turn on can you steam OK?