If it is a BPX error code then you can use TSO BPXMTEXT 6E110533
JRCinetBadName: The Cinet is configured and this name does not match any
stack.
Found this on the IBM Website
Planned IBMLink Outage May 30 - June 1
23 May 2008
This is to inform you that IBMLink will have a planned outage starting on
Friday, May 30 at 8:00 PM Eastern Time through Sunday, June 1 at 5:00 PM
Eastern Time (Saturday, May 31 from 00:00 UTC to
Could you provide an messages or error codes that are occurring with the mount?
Lizette
User has a dataset on a 3590 tape that is not assigned to our ATL. The tape
according to TLMS is offsite, but the OPS crew says it's here and that isn't
an
issue. The user tries to mount it on an external
There were some very nice SHARE presentations on STP. Can you go to the
SHARE.ORG website and look them up?
Lizette
[] -- Snip
Hi everybody!
We are planning to implement STP with the new z10 processors. We read STP
Implementation Guide and STP Planning and one thing remains unclear - how
Of course I forgot that ISPF has its own ENQ display. To find an enq I try
to RENAME the file under 3.4. This usually gets an exclusive ENQ and by
hitting the PF1 (HELP) key, I can usually see who else has the resource.
Lizette
[] -- Snip
Are you looking for tools strictly under TSO? Or
As I prepare to go to z/OS V1.9 my security officers have requeseted
information on how to setup the AXRUSER for System Rexx. I have gone through
many manuals and still cannot determine what the security setup will be.
We are a Top Secret shop, so we need to determine how to setup the userid
I guess I get a little confused with this type of discussion because of what I
have heard from IBM for zCDP.
From what I understand, for zCDP to work (especially for DB2 Backup Recovery)
the Usercats need to be on the same pools as the DB2 Application data sets,
and a second usercat for the
When did this start to occur? My guess would be the 0F13 abend code that is
documented on the ADR049E (001)-STEND(01), 2008.154 12:01:48 DFSMSDSS FUNCTION
TASK ABEND RECOVERY ROUTINE WAS ENTERED. SYSTEM ABEND CODE=0F13
A SF13 might be a missing SVC.
Lizette
: Re: DSS can't backup to tape
However, my error was due to teh JOBLIB being the new SMPE maint but my steplib
was pointing to the SCEERUN2 data set. There was nothing that hit the SCEERUN2
data set with my GIMUNZIP maint.
But once I moved SCEERUN2 from the STEPLIB to my JOBLIB (no steplibs at all)
everything ran good.
I just got this error on my receive. Check to see if you have a JOBLIB and
STEPLIB in the JCL. If so, more the STEPLIB to the JOBLIB.
The other thing that got me was some maintanence that went in on GIMUNZIP. I
had to move some JAVE USS entries to the production JAVA USS Paths. But I
I am building a job to dump and restore my target libraries from zos19 to my
new Res volume.
I used the following control cards to dump my target libraries with no
problem
DUMPDATASET(INCLUDE(ZOS19.**-
)-
The files are not to be cataloged, only copied from my target SMP/E Libraries
to my new sysres as UNCATALOGED data sets. I really do not want to trash my
live system. Or do I need to find another way to build my sysres?
Lizette -
[] Snip
According to message ADR380E discription -
Data
I want to thank Mark Jacobs and Mark Zelden and everyone else for their help
both on and off list while I got my hands around the zFS functions in z/OS
I was able to successfully IPL my z/OS V1.9 Serverpac yesterday with all zFS
files for USS. So I went from all HFS to all zFS without issue so
This is a good webcast and fast. I attended it in March 2008 and it covered
everything at lightning speed. But it is very through. The handout is a
definite plus to download before the presentation. It really helped me
prepare for my z/OS V1.9 upgrade.
Lizette
David Andrews wrote:
On Wed,
What level of operating system are you on? If z/OS V1.9 and above, then
there is an SDSF REXX interface.
Otherwise you probably need to run batch SDSF and select the information you
need. Check the archives for IBM-Main, This has been discussed.
Lizette
Hello.
Is there any way by
Depending on the number of records in the input file, EXECIO may not be the
most efficient way to do this.
But you could create a new file with the new lines in it and then use
something like IEBGENER later in the REXX to mod the data from the original
file into the new file.
The reason to do it
Howard
ICE099A
BLDL FAILED FOR ddname DATA SET
Explanation:
Critical. An error was detected during member verification when the
identified data set was defined as a member of a partitioned data set or a
PDSE. The BLDL system function was used for verification. The most likely
cause is that the
Could you start your CICS like this
S CICSXX,MSGCLASS=A
Assuming Class A is standard SYSOUT.
The OUTPUT would be just for the JCL sysouts I think.
Lizette
Hi, All,
Running z/OS 1.9, JES2.
Like presumably most shops, we've configured JOBCLASS STC to send the
joblog, et al to the bit
I place all of my system OMVS data sets on a separate 3390-9 volume. I have
increased the space on the SYS1.OMVS.ROOT to about 6 trks. Since I am
not using a top ROOT dataset which just have links in it (the better way to
go), I wanted to make sure I had sufficient space.
I have an HFS
Peter,
I totally agree with your statement, however, the descriptions and diagrams
are very nice in this manual. I am still going through the zOS v1.9 manuals
to see what has been enhanced. But my basic direction is to start at the
beginning of the yellow brick road and move forward. I find
Do you have SYSPLEX(YES) coded in your BPXPRMxx Member or SYSPLEX(NO)?
Lizette
I have 200 plus HFS files which are not getting backed up nightly due
to HSM
Autobackup being started on one system and some of the files are
mounted
on different LPAR's and these files need to be backed up
Here is a good REDBOOK, Figure 6.x is the example I will use to begin
setting up my top root
http://www.redbooks.ibm.com/abstracts/sg247035.html?Open
UNIX System Services z/OS Version 1 Release 7 Implementation SG24-7035-01
Lizette
You might want to join the TSO Rexx newsgroup.
For TSO-REXX subscribe / signoff / archive access instructions, send email
to [EMAIL PROTECTED] with the message: INFO TSO-REXX
Look at the DO FOREVER process in REXX. It will continue the loop until you
tell it how to get out.
DO FOREVER
Say
We have DFSORT because we have DB2 V8 and V9. So, I am getting a message
ICE191I 0 DFSORT SVC NOT AVAILABLE - PERFORMANCE MAY BE DEGRADED
Since we did not install DFSORT, we did not follow any installation
process. I am wondering if I need to go back to the install manual for
DFSORT and
Perfection. Thanks. For some reason I was not finding it with my searches.
Lizette
We have DFSORT because we have DB2 V8 and V9. So, I am getting a
message
ICE191I 0 DFSORT SVC NOT AVAILABLE - PERFORMANCE MAY BE DEGRADED
Since we did not install DFSORT, we did not follow any
Check your allocation of your HFS it is not a PDS dataset
TTSMV14.JAVA.HFS
It should say HFS for data set type
Lizette
Thanks for the quick reply. Are there SITE commands needed (I am in
binary
mode)... when I try to FTP to a new HFS I get
ftp bin
200 Representation type is Image
ftp
On Thu, 23 Oct 2008 11:19:47 -0500, Paul Gilmartin
[EMAIL PROTECTED] wrote:
On Thu, 23 Oct 2008 11:34:59 -0400, Lizette Koehler wrote:
Check your allocation of your HFS it is not a PDS dataset
TTSMV14.JAVA.HFS
It should say HFS for data set type
Yes, but IIRC for DSNTYPE=HFS, DSORG
-0500, Paul Gilmartin
[EMAIL PROTECTED] wrote:
On Thu, 23 Oct 2008 11:34:59 -0400, Lizette Koehler wrote:
Check your allocation of your HFS it is not a PDS dataset
TTSMV14.JAVA.HFS
It should say HFS for data set type
Yes, but IIRC for DSNTYPE=HFS, DSORG=PO. ?!?! Thus the absurd
A zFS is defined as a VSAM Linear Dataset. So basically VS. However, then
you need to use the formatter program to make it the zFS it needs to be.
Lizette
On Thu, 23 Oct 2008 11:34:49 -0500, John McKown wrote:
Yes, but IIRC for DSNTYPE=HFS, DSORG=PO. ?!?! Thus the absurd
message.
John,
Were you running a larger number than normal jobs? The BERT is value is
based on the number of JQEs defined on the system which relates to the
number of Jobs.
So if you normal run 100 jobs daily but this time you ran 15000 jobs, then I
can see the need to increase the number of BERTS.
That will depend on what you use to access the file. And what kind of data
you are trying to work with. This is probably specific to your shop.
Are you going to use DFSORT, Syncsort, a Cobol Program, REXX, SAS or some
other facility?
Most languages can provide a DATE-7 Days function. But you
I am looking for a good (and easy) way of ensuring that certain programs only
run on a specific LPAR. We are very vanilla z/OS V1.9.
I was thinking of either creating a stub module that is the name of the program
and then testing to see if it is submitted with /*JOBPARM or creating a TSO
The intent was to do it for the users, rather than have them change their JCL.
As you know, it is not always guarantee that the user will do what is needed.
Lizette
I am looking for a good (and easy) way of ensuring that certain
programs only run on a specific LPAR. We are very vanilla
I would love to use this approach but we are a Top Secret Shop and not RACF.
I will see if our security admins can change this to a TSS function.
And yes, both processes are really required. Fail it on systems where it is
not suppose to run, and make it only run on the LPAR of My choice.
I found this on IBM.COM
http://www-03.ibm.com/systems/z/hardware/connectivity/news.html
High Performance FICON for System z (zHPF)
zHPF is a performance and RAS enhancement of the System z architecture and the
FICON channel architecture implemented exclusively in System z10. By exploiting
zHPF
List -
I have been wrestling with this for a couple of weeks. Thought I had it fixed
but it still shows errors.
When I display my VTS
RESPONSE=SDH8
CBR1110I OAM library status: 410
@BAMA.UA.EDU
Subject: Re: How to correct tape errors
Lizette Koehler wrote:
List -
I have been wrestling with this for a couple of weeks. Thought I had it
fixed but it still shows errors.
When I display my VTS
RESPONSE=SDH8
] On Behalf Of
Lizette Koehler
Sent: Thursday, November 06, 2008 12:13 PM
To: IBM-MAIN@BAMA.UA.EDU
Subject: Re: How to correct tape errors
I will check that out.
I know that the one shipped by IBM is in SYS1.LINKLIB at the top of the
linklst and the one for CA1 is in the SYS1.CA1.LINKLIB data set
that out.
I know that the one shipped by IBM is in SYS1.LINKLIB at the top of the
linklst and the one for CA1 is in the SYS1.CA1.LINKLIB data set which is
further down.
Lizette
Lizette Koehler wrote:
List -
I have been wrestling with this for a couple of weeks. Thought I had it
fixed
Our shop uses T-REX. If I ever have a question on how to do something with
T-REX I just send in a question to their support group and it is provided
very quickly.
We use it for DR to clean up the Master Catalog and it works like a champ.
Installation and usage is very easy.
Lizette
We are
Ray,
What about terminal screen size? Are all users using the same 3270 device or
are some reconfiged for a MOD3, MOD4, or MOD5?
One thing I would look at is the terminal size. Then I would look to see if
maybe some have an ISPF concatenation process. The use of ISPF TEST might be
helpful
I was wondering (though I might be wrong) if the use of INCLUDE statements
might not help.
Inside the PROC itself you could have
//IGYCW PROC
//COMPILE EXEC PGM=x
// INCLUDE MEMBER=DEVEL1 Developers Copylib Dataset
// INCLUDE MEMBER=APPL1Specific Application Copylib Dataset
//
I am trying to determine what the difference in response to these two CA1
messages are. The CA1 Messages manual has
IEFTMS7 IPL DATE MORE THAN 8 DAYS FROM LAST IPL
IEFTMS3 PREVIOUS IPL DATE = date
IEFTMS8 VERIFY DATE = date OR 'HELP'
Reason: The current system date is eight or more days beyond
I would recommend a read through the Distributed File Service zSeries File
System Administration SC24-5989-07
Lizette
What utility do I use to allocate a ZFS file?
JL
Jason Lowe - Mainframe Systems - Cornell Information Technologies
[EMAIL PROTECTED]
(607) 255-7851
The Supreme Court has
How much memory do you have on the system? DB2 will page like crazy if there
is not sufficient. I have 14GB on my heavy DB2 Lpar and it never consumes the
paging datasets.
Prior to that I did not have sufficient real memory and got paged to death.
Lizette
I have a situation with our page
I have been racking my brain trying to remember how to do this (again).
I have a series of replicated devices that should be offline at IPL. If they
are not, then I get IEA213A DUPLICATE VOLUME which really annoys operations.
In the IODEF they are defined as online. In my COMMNDxx they are
I would be curious to see the whole message. The IEC161-040 indicates a
problem with the catalog and an IDC3009I should be reviewed. The 002 is
insufficient to see which IDC3009I message to look at. Is the space change for
a VSAM data set?
IEC161I (return code 040) rc[(sfi)]-ccc,jjj,
Can you explain what you are trying to do?
Are you looking for Backup/Recovery? Allocation, Cleanup?
I have not heard of a product called a PDS Manager. There are many products
that can assist in the support of PDS datasets like DFHSM, PDSMAN by CA, and a
few others. Some are freeware,
I had posted a query on the MXG list about reporting on zIIP usage via the
PROJECTCPU function in IEAOPT.
I got a wonderful response back from Al Sherkow. One of the points he made
surprised me a bit.
Apparently if there are no zIIP or zAAP engines, some ISVs will not make their
SRB's
Is your user using 3.4 or Opt 2(EDIT) to do this?
If option 3.4 I would have the user do
Go to 3.4
On the line next to the data set enter
e /(x) -- Member does not need to exist
Have the user check the next panel that is displayed.
I have tried a couple of times to get to IBMLINK and keep getting the invalid
path panel.
Any one else having trouble with IBMLINK this morning?
Lizette
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send
Thanks Alan,
Now I do not feel like I am going crazy.
Lizette
-Original Message-
From: Field, Alan C. [EMAIL PROTECTED]
Sent: Nov 19, 2008 9:41 AM
To: IBM-MAIN@BAMA.UA.EDU
Subject: Re: IBMLINK unavailable
I have an ETR open from yesterday and got this email right before your
post:
Try using ISRDDN. On the command line enter ENQ
Then enter in the data set name.
Other option is to try and rename in 3.4. If it is allocated, you should get
and error message. By pressing PF1 you should see the holders.
WHOHAS ia a CBT Tape program. You would need to install that in your
I believe that SMF data is GMT clock time, so the likihood of duplicate records
is very small.
If you run off of local time rather than GMT, then that might be possible.
Lizette
On Thu, 20 Nov 2008 13:52:14 -0500, Kempf, Ted
[EMAIL PROTECTED] wrote:
Hey John, With that SET TIMEZONE... Any
Just in case you were wondering, a new option in z/OS V1.9 for Unix
ISPF Option 3.17
Tutorial - z/OS UNIX Directory List - Line Commands - Tutorial
Option ===
You might want to download Marna's 3 part share presentation on z/OS V1.10. It
will have lots of good information on going from different releases to 1.10 as
well as what you need to look out for.
If you cannot download it let me know.
I have found that putting on all the compatibility maint
, Lizette Koehler [EMAIL PROTECTED] wrote:
From: Lizette Koehler [EMAIL PROTECTED]
Subject: Re: z/OS upgrade
To: IBM-MAIN@bama.ua.edu
Date: Friday, November 21, 2008, 3:38 PM
You might want to download Marna's 3 part share presentation on z/OS V1.10.
It will have lots of good information on going
Do you have a LOGON EXIT in place? Something like IKJEFLP1
Lizette
They do use Blue Zone, No scripts that I can find. Logoff is normal TSO
logoff command.
Every time they log off the next time the S is back.
Security package is RACF, Nothing in the TSO segment for mail/Nomail or
I have source code that is not currently managed by SMPE. I would like to
place it in SMPE control by developing a usermod to do the assemble and link.
I have not done this type of usermod before and after reading the manuals I
think I am close but just am not getting what I want.
The source
Thanks Binyamin and Mark Z.
I was missing the UCLIN part. Now that I have that coded, it is working great.
Big hugs for the help. Or is that PC incorrect?
Lizette
On Mon, 24 Nov 2008 10:58:16 -0500, Lizette Koehler
[EMAIL PROTECTED] wrote:
I have source code that is not currently managed
In your IDCAMS step you can reset the MAXCC for the step which could be checked
out by next steps.
//IDCPROC PROC DSN1=
//IDCAMS EXEC PGM=IDCAMS
//SYSPRINT DD SYSOUT=*
//DSN1 DD DSN=DSN1,DISP=OLD
//SYSINDD *
DELETE FILE(DSN1)
If LASTCC 0 Then Set MAXCC=22 /* Set Step return
I have some basice questions on setting up the Tape Encryption on our TS3500.
We have installed JAVA 1.5. I have a Data Class defined. I have an ACS
routine to limit who can specifiy the encryption on tape.
My basic Q's (and I have read the Planning Guide, the TS3500, and TS1120
Manuals and
Tommy,
Have looked at the STORAGE Tools that are in the
ftp://ftp.software.ibm.com/storage/tapetool/
Directory? There might be some examples there. VOLLIST, IBMTOOLS etc...
Lizette
I am looking a program which can read all user catalog information
from master cataloganyone have an
See if this link is what you are looking for.
http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/MVS10DA1/CCONTENT
S?SHELF=IEA2BK90DN=NADT=20081112100913
or tinyurl
http://tinyurl.com/5fh5ef
Title: MVS Data Areas Volume 1 (ABEP-DCCB)
Build Date: 11/12/08 10:09:13 Build
Mark, do you have PTFon your SMPE 3.4 system?
FIXCAT HOLDDATA is incompatible with prior releases of SMP/E. It can only be
processed by SMP/E 3.5. Coexistence APAR IO07480 is provided for SMP/E 3.3 and
SMP/E 3.4 to enable those releases to silently ignore the FIXCAT HOLDs when
they are
, 2008 at 2:37 PM, Lizette Koehler [EMAIL PROTECTED]wrote:
Mark, do you have PTFon your SMPE 3.4 system?
FIXCAT HOLDDATA is incompatible with prior releases of SMP/E. It can only
be processed by SMP/E 3.5. Coexistence APAR IO07480 is provided for SMP/E
3.3 and SMP/E 3.4 to enable those
An S013 abend usually indicates writing to a data set that was not allocated
Explanation: The error occurred during processing of an OPEN macro
instruction. This system completion code is accompanied by message
IEC141I. Refer to the explanation of message IEC141I for complete
I would probably add a LENGTH variable to account that the string length for
testing my change if you second field is longer or shorter than expected. It
might help to add WRITE statements to see what things look like when checking
out IF tests.
SET LL = LENGTH(field)
IF
What control cards are used for the ICKDFS init?
The ones I use cause a RC 12 when a unit is online and trying to be clipped.
INIT UNITADDRESS(7A1A) VERIFY(EM7A1A) VOLID(Z19DL2) -
VTOC(2,0,120) INDEX(0,1,29)
Lizette
We just had a problem were one of
I am trying to setup my EMK Profile for JAVA. I keep getting errors on teh
Audit. statements. Mostly FSUM7351 not Found.
Java is mounted (J1.5), EKM paths are mounted. Not sure what is missing.
Has someone already set this up and would share their insights of how to config
JAVA for EKM?
Howard,
Does this data set exist? TDB.SYSPROG.SYMD.CAVHPROT.CLUS
Lizette.
-Original Message-
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of
Howard Rifkind
Sent: Monday, December 08, 2008 3:29 PM
To: IBM-MAIN@bama.ua.edu
Subject: Tape Space Issue
Perhaps I am confused.
The output dataset is
E18823.TDB.SYSPROG.SYMD.CAVHPROT.CLUS
The VSAM data set that is to be exported is
TDB.SYSPROG.SYMD.CAVHPROT.CLUS
The error message indicates no space for IGD17045I SPACE NOT SPECIFIED FOR
ALLOCATION OF DATA SET TDB.SYSPROG.SYMD.CAVHPROT.CLUS
Which
Here are the messages. I removed the comment cards. This is from the Start of
the EKM STC until it terminates.
Lizette
JVMJZBL2004N Log level has been set to: T
JVMJZBL2999T - JzosVM()
Thanks everyone so much. My paths, libpaths and minor little JAVA JZOS
configuration issues are resolved.
I am not off to get my environmentals parms up to snuff and I should be good to
go.
Lizette
--
For IBM-MAIN subscribe
While working on implementing EKM, I noticed that JAVA 6.0 is out.
When it comes to JAVA is it better to upgrade it now or should I wait? Is 6.0
causing any issues?
Lizette
--
For IBM-MAIN subscribe / signoff / archive
To: IBM-MAIN@bama.ua.edu
Subject: Re: Anyone using JAVA 6.0 on z/OS?
On Thu, 11 Dec 2008 13:16:32 -0500, Lizette Koehler
stars...@mindspring.com wrote:
While working on implementing EKM, I noticed that JAVA 6.0 is out.
When it comes to JAVA is it better to upgrade it now or should I wait? Is
6.0
Have you looked at the SETUNI command in MVS?
It may do what you need.
Have you opened an ETR to IBM? If you have established Unicode on Demand, then
my understanding is that when a new code is requested, it gets built.
Lizette
-Original Message-
From: Jim McAlpine
My prefrence is FB 80 80x
That way it fits on my screen and I do not have to scroll left and right all
the time.
Downside, I cannot indent the way I like within 80 col.
Lizette
-Original Message-
From: Rick Fochtman rfocht...@ync.net
Sent: Dec 17, 2008 12:15 PM
To:
Eric, to date, I have not received any emails with that title.
Lizette
Has anyone else gotten an email with the same subject that I quoted above? I
got an email yesterday, and then I got the same email today. Is IBM really
moving these links, or is someone scamming me?
Eric
Could you provide the ICE messages you got?
Lizette
getting a rc 16
jcl below:
PKSC9.TSS.JCL(MDLSEC1)
//REPORT EXEC PGM=ICETOOL
//RACFDATA DD DISP=SHR,DSN=IFXZDL.RACF.UNLOAD
//TEMP0001 DD
Thanks to several people onlist and off, I have finally gotten my EKM Server
running on my LPARs.
What I have run into is that the software does not seem to select any tape
drives.
I have drive.acceptUnknownDrives = True coded
I have ensured the tape drives, controller and Specialist all
-Original Message-
From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On Behalf Of
Lizette Koehler
Sent: Friday, December 19, 2008 12:50 PM
To: IBM-MAIN@bama.ua.edu
Subject: EKM and Selecting Tape Drives for Encryption
Thanks to several people onlist and off, I
One trick I like to use - go to option 3.2 and allocate the file in MB in
the panel. Then copy the current dataset to this new one and see how much
space was requested in MB. Requires no math. Use the same attributes
except instead of cylinders use MB.
Lizette
The other process is a nice little .exe from Central Coast Software which is
free called DASDCALC.
www.centralcoastsoftware.com
It runs on windows and you can plug in the attributes and it will calculate the
space in B, KB, MB, GB.
I use it all the time for files on the PC to mainframe
running z/OS V1.9 with JAVA in Unix
I would like to know if there is a way to establish the JAVA in UNIX to always
get the system date and time. I would like to reduce the need to update the TZ
parameter each time the time jumps.
I do have an /etc/profile which is fairly basic. As shipped by
No - it is getting GMT. We are EST.
Lizette
-Original Message-
From: Rich Smrcina rsmrc...@wi.rr.com
Sent: Dec 29, 2008 9:34 AM
To: IBM-MAIN@bama.ua.edu
Subject: Re: UNIX and System time in z/OS
Lizette Koehler wrote:
running z/OS V1.9 with JAVA in Unix
I would like to know
As always - more than one way to skin a cat.
All excellent answers and now I must dig deeper and deeper into UNIX and the
/etc folder. I knew about the /etc/profile. I did not know about the
/etc/init.options. So many places so little time. And yes, it would be nice
if IBM set it up with a
It looks like there is a space between the comma and the D A,L.
Have you tried it without the space? RO LPAR2,D A,L
Lizette
hi all,
Why the RO command does not work properly? is there any changed after
upgrade to z/os 1.9.
In our shop there are three members or LPARs connected to
(outputvar.c,80)
MYRESULT=AXRMLWTO(line,'CONNECTID','D');
IF MyResult =0 THEN
EXIT 1;
END;
CALL AXRMLWTO , 'CONNECTID','E';
END ;
On Tue, Dec 30, 2008 at 7:31 AM, Lizette Koehler
stars...@mindspring.com wrote:
It looks like there is a space between the comma and the D A,L
As far as I know there is no command to tell you what a jobclass definition is
for a specific shop. The system (JES2 or JES3) will have A-Z, 0-9 for any job
class, msgclass.
The $DJOBCLASS( ) will tell you about a specific class. For example
$djobclass(a),long
Is it possible to create a shell script to execute at startup time in EKM to
produce a startup message? Ad if I could do this at shutdown time as well -
awesome.
Have it say someting like EKM0001I EKMESRVER on SYSNAME is Up on date / time
If so, since I am not shel oriented how could I do
, Mainframe Services
david.jou...@53.com
1830 East Paris, Grand Rapids, MI 49546 MD RSCB1G
p 616.653.8429
f 616.653.8497
-Original Message-
From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On Behalf Of
Lizette Koehler
Sent: Tuesday, December 30, 2008 1:48 PM
To: IBM-MAIN
I have already done that. A requirements hasw been accepted. But with
ported applications I am not sure how long it will take for IBM to action
this. Not enough z/OS Users or tape encryption to put pressure on sooner
than later.
So in the meantime, I am hoping a shell script could be created
requesting identifiable messages.
--
Peter Hunkeler
Credit Suisse
Date:Wed, 31 Dec 2008 05:40:33 -0500
From:Lizette Koehler stars...@mindspring.com
Subject: Re: Shell Scripts in EKM
I have already done that. A requirements hasw been accepted. But with
ported
We are going to try that next. I was hesitant since I was not sure if that
would prevent us from using MODIFY commands against the STC.
The other thing is I was always taught to ensure there were MESSAGE IDs on any
messages I produced. It did mot matter if mainframe or other. I am not sure
Howard,
It will depend on what type of processor you have. I think it is based on
number of CPUs and MSUs.
For my Shop on one z890 with an enterprise license - I think we were in the
$100,000 per year range for the whole enchilada.
We now have only 5 IDs with only a basic ETR support.
How would I code the EKM paramenter to include a date and time stamp? I want
the process to generate a new file each time it is cycled. Or is that not
something I can do with EKM? I would also like to make the system name
symbolic as well. I have been reading my EKM and UNIX manuals but
So how do you get the Big Plasma TV? Does your company give you a bonus for
saving money??? ;-D
Lizette
...but what is the issue? g
Trying to save cost and buy myself a plasma TV :)
I want maintain product swap out flexibility at the software level. I
starting to lean toward the
This is a new Flashcopy function. Here is the text for Apar OA15791
NEW FUNCTION: Space Efficient FlashCopy ( SEFLC )
Local fix
Problem summary
* USERS AFFECTED: All DFSMSdss release 1K0 and higher users*
* of
Is this for IMS, CICS, Batch or other environment? What level of z/OS would
you be running this on?
Cics has CLER for seeing the options, and I think IMS may also have one for the
online side.
If you are at z/OS V1.9 then the parms might be maintained in CEEPRMxx in
SYS1.PARMLIB or a CEEOPT
101 - 200 of 1752 matches