Re: [weewx-user] Re: levels, cable length for Vantage Pro 2 datalogger

2018-02-12 Thread Liz
On Mon, 12 Feb 2018 18:00:57 -0800 (PST) JE Norton wrote: > Hi Greg, FWIW, I have a serial cable that is about 100 feet long and > my station has been operating for 5 years > John > > On Saturday, February 10, 2018 at 6:13:37 PM UTC-7, Greg Troxel wrote: > > > > I have

[weewx-user] Re: Change archive interval for single report

2018-02-12 Thread gjr80
If your pages are updating at 10 minute intervals that sounds like the archive interval being used is 10 minutes (if you are using the SteelSeries skin that would further support this idea). With a Davis station any archive interval setting in the console will override the [StdArchive]

[weewx-user] Re: Change archive interval for single report

2018-02-12 Thread gjr80
A.J., Exactly what did you stumble across as there is a skin and an extension that can produce the gauge-data.txt file used to drive the SteelSeries Weather Gauges. Firstly there is the SteelSeries skin that generates gauge-data.txt via a

[weewx-user] Re: Change archive interval for single report

2018-02-12 Thread A.J. Burnett
Hi Andrew, Station type is a VP2. My StdArchive interval is set to 300, which should be every 5 minutes, but the gauge-data.txt file only updates every 10 minutes. My web page only updates at that same 10-minute interval too. -- You received this message because you are subscribed to the

[weewx-user] Re: Change archive interval for single report

2018-02-12 Thread Andrew Milner
Loop interval depends on your station type AFAIK. Is 10 minutes your archive interval? On Tuesday, 13 February 2018 05:11:09 UTC+2, A.J. Burnett wrote: > UPDATE: > > I stumbled across SteelSeries Gauges and saw that it produced a great JSON > file (and has some cool gauges to go along with

[weewx-user] Re: Change archive interval for single report

2018-02-12 Thread A.J. Burnett
UPDATE: I stumbled across SteelSeries Gauges and saw that it produced a great JSON file (and has some cool gauges to go along with it too!). So I have a JSON file now, but I want SteelSeries to update every 2.5 seconds (near real-time). I can't find that interval anywhere...right now, it

[weewx-user] Re: Database not updating

2018-02-12 Thread gjr80
Hi, Data is great but logs are better :) Quite possible you have corrupt station memory (have a look here in the User's Guide), not uncommon when disconnecting/interrupting power to a Davis station. If you want to take a

[weewx-user] Database not updating

2018-02-12 Thread JE Norton
Just did a new install on a Debian computer. I have a Davis Vantage Pro station (was using an older version of weewx 2.01, which was installed with setup.py). I decided I'd deal with historical data later, or not, since it is all on CWOP anyway. So I downloaded the .deb file for the current

[weewx-user] Re: levels, cable length for Vantage Pro 2 datalogger

2018-02-12 Thread JE Norton
Hi Greg, FWIW, I have a serial cable that is about 100 feet long and my station has been operating for 5 years John On Saturday, February 10, 2018 at 6:13:37 PM UTC-7, Greg Troxel wrote: > > I have a Vantage Pro 2 with a recent datalogger, and with the included 8 > foot RJ11 extension cable and

[weewx-user] Re: WMR300 testing LAST Driver

2018-02-12 Thread Cameron D
Two problems with RC5 so far... 1. There is still something wrong in the history code, with more bogus history records being reported.. I have not yet worked out if it was a fault in my original code or in the recent adaptation. Even though I am saving every minute, I still have to wait about

[weewx-user] Re: Change archive interval for single report

2018-02-12 Thread A.J. Burnett
Hi Gary, Thanks so much for your response! I'll admit, I'm very lost. I have done some minor customization to templates and have some basic Python knowledge, but I'm not understanding the steps in your very detailed message (thanks again!) Perhaps harnessing the loop packets is the way to go,

Re: [weewx-user] Re: mysql database queries rxCheckPercent

2018-02-12 Thread kkruzich
Thank you very much Gary! This is exactly what I was hunting for. Much appreciated, -kkruzich On 2/11/18 8:25 PM, gjr80 wrote: Hi, The data in the rxCheckPercent field in table archive is probably what you are after, archive holds the per archive period data. The

Re: [weewx-user] Modified schema for my sqlite database

2018-02-12 Thread Tryphon Cosinus
1. Yes I used the setup.py method and the database in weewx/archive/ 2. cd weewx/archive echo "select count(dateTime) from archive;" | sqlite3 weewx.sdb -> 212000 records echo "select count(dateTime) from archive;" | sqlite3 weewx.sdb_new -> 30 records Both weewx.sdb

[weewx-user] KlimaLogg Pro - Auto USB setting

2018-02-12 Thread Luc Heijst
The newer version of the KlimaLogg Pro main station has an extra basic setting: Automatic USB-connection: ON/OFF. (For example: manufacture date 08/2017) The default setting of Auto USB is ON (activate). When activated the device tries to connect at every full hour. Note: elder versions of the