-Original Message-
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Timothy Sipples
Sent: Thursday, February 14, 2008 7:17 AM
To: IBM-MAIN@BAMA.UA.EDU
Subject: Person-Months for Version-to-Version Migrations?
The discussion here about how many z/OS system
John,
Sounds like things are looking up for you!
snip
Perhaps so! [grin} Our new head of Open Systems is said to be an AIX
bigot. I've heard it said that he wants to replace as many Windows
servers (Intel) with AIX servers (pSeries) as possible. Well, it's a
start. I've also heard that he would
Never had to do this myself, but:
Why not create the second image in the new sysplex and populate your
CDS's in the new sysplex.
Migrate work to the second image in the new sysplex and then put the
current image into the new sysplex with an IPL.
I would expect this to be a minimal outage ( 30
Shared Spool?
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html
It is!!
snip
snip
Pat Mihalec wrote:
I haven't been following this but has anyone suggested setting up a
CTC
between the LPAR's. The connection is setup over Escon channels.
Or, better yet, TCP/IP over HiperSockets should be *screaming* fast --
assuming the LPARs are on the same CPC.
snip
What would be a comfortable paging subsystem configuration, especially
for the Production LPAR, as to individual size and (especially) number
of page datasets?
/snip
IMO, the largest needed paging subsys can be determined as follows:
1) Determine actual working set in use. This is easy if
If the UCATs do not exist, export them with a DCON (see the FM). This
should clean up the VVDS.
If that fails use DELETE VVR RECOVERY. The RECOVERY options tells VSAM
the volume has been destroyed and is being recovered.
HTH,
snip
I am trying to expire a volume that has a catalog on it. The
snip
I have to migrate a ML1 to ML2. Below is the command I will use:
HSEND FREEVOL MVOL(HSM002) AGE(0) TARGETLEVEL(ML2)
My question is once the migrate has completed do I need to issue
command :
HSEND FREEVOL MVOL(HSM002) TARGETLEVEL(ML1)
/snip
Why bother? Just let the date live
snip
1) Does IDCAMS keyword NOSCRATCH make HSM bring in a dataset before
deleting it just like NONVSAM does? I may have observed that
behavour...job
had NONVSAM NOSCRATCH and HSM brought it in first, after I removed the
NONVSAM and I think it still came in (didn't confirm conclusively) until
It is probably waiting for an interrupt from the device. Hit RESET/ENTER
and it should wake up..
snip
Is anyone out there using ICC for a z/OS console. We are switching over
from our 3174's and started to use ICC consoles so I thought id ask our
operator to do a SAD from it. The first problem
The coding for the SAD looks good to me. If all else fails, the HCM can
be used to control the SAD...
It is probably waiting for an interrupt from the device. Hit
RESET/ENTER
and it should wake up..
snip
Is anyone out there using ICC for a z/OS console. We are switching
over
from our
Since this is a family list G I cannot use the true language needed to
Express my opinion. I will have to paraphrase!
Horse Manure!
While many of the points are valid, the conclusion is not.
Remember CASE and then case? Where are they now?
snip
http://blogs.zdnet.com/projectfailures/?p=666
QDF (quick dirty fix) is to set TSO period 2 to importance 3.
This should change things from intolerable to manageable G
If you want no further calls for ever and ever, Set TSO period 2 to
importance 2. This will place TSO ahead of PRODHI. (be careful!).
RMF SYSRPTS(WLMGL) provides a wealth of
IIRC the durations are cumulative (and inclusive).
e.g. Per 1 dur 1000
per 2 dur 1 (includes the previous 1000)
per 3 (unending)
IOW, PER 1 (and associated characteristics will last for the 1st 1000
SU's
PER 2 (and associated characteristics will last for the next
After 5000..
snip
One more question. Are the durations cumulative or per period? i.e. if
I
setup as follows, does a transaction fall to period three after 5000
service
units or 7500? I looked in the redbook System Programmer's Guide to:
Workload Manager but couldn't find the answer.
#
Thanks for the update
SNIP
snip
One more question. Are the durations cumulative or per period? i.e.
if
I
setup as follows, does a transaction fall to period three after 5000
service
units or 7500? I looked in the redbook System Programmer's Guide to:
Workload Manager but couldn't find the
The operating system does not know anything about the MVC's. MVC's are
mounted on drives direct attached to the VTS, bypassing MVS IO entirely.
The only places in MVS land that know anything about the MVC's are the
TMC (where they are usually marked in delete status) and the HSC CDS's.
Virtual
From the deep dark mists of time G
IIRC, the tuning methodology is to issue D NET,BFRUSE at periodic
intervals and adjust the settings in ATCSTRxx accordingly so that buffer
expansion/contraction is minimal.
There were many tricks with the SNA definitions that have probably been
committed to
SETMIG DSN() MIGRATION should take care of it..
35.3.1 COMMANDMIGRATION | MIGRATION | NOMIGRATION: Specifying the Way
Space Management Is Controlled
Explanation: COMMANDMIGRATION | MIGRATION | NOMIGRATION are mutually
exclusive, optional parameters specifying how space management is
Please post your SMP/E control statements.
Apply S(xxx) will return SYSMOD missing. Apply S(yyy)
groupextend will usually suppress this message unless xxx is not
superseded by yyy.
If the message persists, xxx is a pre-req for something else that
does not supersede xxx.
Actually, with the proper investment in application/planning, it *IS*
zero down time.
snip
But it is not ZERO down time.
It is simply LESS downtime. In our shop, to simply recycle a CICS region
(down then up) takes a minimum of about 10 minutes (no, I've not done a
stop watch on this)
/snip
Of
The messages indicate delay's in XCF processing.
Are you by any chance running an ICF on a shared engine?
If you are not running a ICF or a CF, check the utilization of your XCF
Communications paths.
HTH,
snip
Does anyone know what causes a SYSTEM STALLED message? We have a
multi-system
XCF communicates over some path. Whether it is CTC's, XF links or other.
The D XCF command is your friend. Check the exact syntax in the MVS
systems commands manual.
HTH,
snip
We have 2 engines, no ICF or CF, and 2 LPARS in a SYSPLEX that share
both
engines. I am unfamiliar with checking the
In this case you will need to research the reason for the 3 ptf's
described in your previous post to have failed. Once that is corrected,
all should be OK.
By any chance is this a new install? In those cases, I have often found
it helpful to receive/apply/accept the base functions first, and then
snip
It seems there's a limitation that SMS won't allow multivolume
allocation.
/snip
Horse manure!
Code your JCL with Unit=(sysda,n) where N is the number of volumes
required to hold the data. I usually code unit=(SYSDA,59) (the max
allowed). There is also a discussion in the manual about the
Thank you, Ed!
snip
If you are an IBM shareholder, unhappy with the amount of your per-share
dividend, stock price/performance, and/or you believe the board to
incompetent or overcompensated, please bring it up at the next
shareholder's meeting ... or not. But, please keep it off of IBM-MAIN!
-Original Message-
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Lizette Koehler
Sent: Wednesday, April 09, 2008 7:40 AM
To: IBM-MAIN@BAMA.UA.EDU
Subject: Re: Modify DSCB information
Jacky,
It depends on what you want to change and the reason for the change.
There is an old program on the CBT Tape (DMOD) that can change many F1
DSCB attributes. I don't know if anyone has updated it for SMS. I last
used this
Program in the early 90's.
HTH,
snip
Is it possible to change the DSCB information of allocated dataset
through
some utility ? Like changing
1.8 and 1.9 (English **, Japanese **J)
Subject: Re: OA22578 NEW FUNCTION (GRS) migrate GRSRNL=EXCLUDE
environment to full RNLs without requiring a sysplex-wide outage
Release 73J
Release 730
Release 74J
Release 740
What releases of z/OS do these correspond to?
Check the EXPIREBV command for backups.
For ML2 I suggest HSEND LIST ODS(x). Edit x to HDELETE commands
and execute in batch or online
snip
I am embarking on a clean up of ML2 dsns. I have encountered a
problem, there is NO Management Class present for about 6,500 dsns which
belong to
The z6 Chip is 4.2 gh, the p6 chip is 4.4 gh.
The p5 chips are plus/minus 2 gh IIRC.
snip
I believe that your statements would hold true if you were comparing an
IFL on the z9 against the p6. As I understand it the p6 chip is a
1.8Ghz chip and the z9 IFL has a 1.2Ghz chip. So if you move from
TSO line edit? XEDIT?
snip
Just out of curiosity, which editor supports that syntax. I know ISPF
would use c all Unix VSAM and I have a vague recollection of vi or
some Unix editor using s/Unix/VSAM but I've never seen the two mixed
before.
.
.
.
One uses the most convenient tools available.
It depends.
In the old SLED days this could be performance crippling, especially if
there was a decent paging rate(remember only one actuator/volume). With
little or no paging this would not be a large problem.
Fast forward 20 years:
Data is mapped transparently to many many small drives,
Check your dump logs. I have found that HSM will retry the failed dump
at some point prior to the end of dump processing.
snip
It appears that HSM will redump a DASD volume if it encounters a tape
error on the first file of a tape or more precisely with the first open
of
a tape. If HSM/DSS
This was documented on pp 236 of the migration guide
snip
Went to z/OS 1.9 yesterday on our main DEV system, which also runs
some
PROD batch. One of our Capacity Performance RMF processing jobs got
an
S806 on module ERBPPSRT. It was pointed out years ago (in this forum)
that this sort
I use a standard OS PDS with the install instructions. JCL/JOBS are
stored in the install: datasets' PDF's for doc are loaded to a standard
LAN directory. I (personally) use the web for most doc lookups, but I
also have the doc on the LAN if needed.
What you have proposed will work just fine, but
Is Wally or Dilbert in the next cube?
Is the PHB in the next cube? Wally, Dilbert?
snip
I would love that. I suggested that. I was shot down. Them: Nobody to
maintain it. Me: I'll do it. Them: Not your job function!
/snip
--
Escon Converter? Plenty around and should be dirt cheap.
Also, if they are still around check out Black Box. The Radio Shack of
the computer world. Had little boxes (use specific) in mutltiudes of
combinations. Cumulatively, they could connect almost anything to
anything else.
snip
I'm currently
snip
What I don't have as yet is a useful equivalent to HSM recycle. But
I'm using virtual tape with 99,999 available volumes.
/snip
You will use those up faster than you think. I would suggest (as a
minimum) at least another 100K volsers, and preferably another 200K
volsers.
Good luck!
This is common if you are far backleveled on your maint. The online
order process only seems to go back one level when you request pre-reqs.
Those pre-reqs may have additional pre-reqs so you will need to order
those separately.
If you have the time, you can do the research yourself with the aid
There is also a message from ASM when, IIRC, the total page slot usage
exceeds 70%. This message will name the top 5(?) users of auxstor.
snip
Hello all, this started this morning and I don't know why. We had to
add
3 additional paging datasets. Is there qnyway to tell who is the
culprit?
WLM managed Init's?
IIRC, Jobs are placed in queue in FIFO order within Service Class.
snip
The thing is, a JES2 supported solution, it seems to me, would be
both ideal and easy to implement. Here's my idea:
(1) support a //card option or a /*card option by which a user could
provide an
snip
Could any of you recommend reference material (web sites, manuals,
redbooks/redpieces) so I could learn something about writing scripts
under ISHELL in a z/Linux environment?
/snip
Try Unix Shell Programming Kochan/Wood
ISBN 0-672-48448-X
LCCCN 89-63718
Hayden Books
According to my z/OS 1.9 installation it should be in DDDEF SISPMACS
In my case, SYS1.SIPSMACS.
HTH,
snip
George Rodriguez [EMAIL PROTECTED] wrote: I've been
searching hi and low for any information on FLMALLOC which
controls the JCL that's submitted to move things around in preparation
for a
Allow mixed case outside of quoted strings.
e.g. SPace=..
snip
Subject: Enhanced JCL processor? (and maybe a few other thoughts)
This is a blue sky idea for discussion. It is not a request to IBM. But
it derives from an earlier thread on the short comings of the current
JCL. So, I was just
This might be a life saving event to someone on currently on
unemployment!
(or worse, whose unemployment has run out!)
snip
This interested me. Not because I want the position, but because I
couldn't believe someone was trying to hire an MVS Systems Programmer at
such a low salary.
Remainder
Having read all of the posts in this thread, I am unsure if the
objective is:
a) to determine if a particular module is loaded from a particular
dataset
or
b) to determine if a JOBLIB/STEPLIB is being used to access this
dataset.
The responses to this thread I have read so far, all seem to be
We are looking hard at this. Based on the number of servers we have to be
consolidated, there are significant potential savings available.
We are at the POC stage. I.E. The financials have been reviewed and look
promising. IBM is willing to make IFLs and z/VM avail on a trial basis at no
snip
InfiniBand Host Bus: I am somewhat aware of what this is. What software
supports it? z/VM Linux only? Or z/OS and z/VSE as well? What about in
the future? From later in the list, is this only for Coupling Facility
links?
/snip
z/OS yes (more recent releases only. 1.8???). Not sure about
1) F DFHSM,LIST TTOC SELECT(FULL)
2) examine listing for PREV/NEXT volumes
3) Find the first volume in the chain
4) F DFHSM,RECYCLE EXECUTE VOLUME(1st vol in chain)
HSM goes through a couple of checks for recycling of volume chains. See
topic 4.2.10 in
snip
I could say replace a 2105 with a 9980 (-2 generation) and get better
Performance.
/snip
Ron, you're forgiven. You contributions to this list far outweigh this
small slip.
I concur with you analysis however, why spend money on old technology.
If budgetary considerations allow, by all
1) Microcode updates are usually documented in ResourceLink.
2) EC holds are usually benign. i.e. the code will install, but be
ineffective until the required MCL is installed. IOW, go ahead and
install the PTF. When the MCL is loaded, the code will become effective.
3) UA90380 appears to be the
It is, but it fools the converter/interperter into thinking there really
is a dataset there and allows the concatenation to proceed, as opposed
to DD DUMMY which truncates the concatenation.
Agreed, the effect at execution time is the same.
snipTry DSN=NULLFILE. See the JCL manuals...
We had
Try DSN=NULLFILE. See the JCL manuals...
snip
I sure wish DUMMY didn't truncate the concatenation, but
were treated as an empty directory (DSORG=PO), or data set
(DSORG=PS), allowing subsequent catenands to be searched
or read.
Or that there were an alternative keword (DD EMPTY) with that
Well Said! Technology is only a benefit when properly applied!
snip
I might well display my ignorance here but why the heck should I care?
What I'd care for is functionality, performance, reliability, and price.
I don't care whether this is reached with RISC, CISC, microcode,
millicode
or any
Is the other end of the connection up?
Did somebody issue a $PNETSRV (? unsure of spelling w/o lookup)
snip
anyone ever recv following msg after startup of NJE/IP link ??
IAZ0543I NETSRV6 TCP/IP connection with IP Addr: 10.239.53.121 Port: 175
Initiated
IAZ0543I NETSRV6 TCP/IP connection
z/800 went EO marketing a little earlier this year. No MES or upgrades
are orderable AFAIK.
http://www-07.ibm.com/systems/sg/z/800/
HTH,
snip
I believe that the 002 comes with 2 GP CP's and 1 SAP configured and 2
spares but I cannot find any document stating that IBM does not support
adding the
There is an open IBM APAR on this I don't have the number handy, but
last time I checked (about mid November) it was still in open status.
HTH,
snip
We have a user that displays a list of datasets in an output group in
the Held
queue of SDSF with a ?. She selects a specific dataset for output
As of a few minutes ago:
OA25382: AFTER OA23460, USE OF THE SDSF JDS PANEL TO MODIFY A SINGLE
DATASET ATTRIBUTE CAN RESULT IN CHANGING ALL D 08/06/04 PTF PECHANGE
APAR status
OPEN
Error description
When the SDSF JDS panel is used to change attributes such
as CLASS or to purge the data set,
Good from here - Dallas
snip
Subject: lbdsoftware.com
I've been told that the site is working now - can someone please confirm
(as it hasn't failed for me)
/snip
--
For IBM-MAIN subscribe / signoff / archive access
SUBSYS=LAM?
-Original Message-
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Paul Peplinski
Sent: Thursday, December 04, 2008 12:10 PM
To: IBM-MAIN@bama.ua.edu
Subject: Can you read CA-Librarian Files without Librarian?
I am looking for a way to read
Try (watch the wrap):
http://www-03.ibm.com/servers/resources/servers_eserver_zseries_zos_wlm_
pdf_cmgbatch_pdf_wlm_goal_based_initiator_management.pdf
http://www-03.ibm.com/servers/resources/servers_eserver_zseries_zos_wlm_
pdf_wlminits_pdf_wlminitsjm.pdf
and
Try http://www-01.ibm.com/support/advsrch.wss?rs=0loc=en_US
Gets you most of the S S information (no ETR,)
No sign on required.
HTH,
snip
Subject: IBM Link Down?
Can anybody get into IBM link? I think it is down.
/snip
You have hit upon the correct solution, change the Management Class.
I suggest the use of PRIMARY DAYS and LEVEL1 DAYS in lieu of
generations on primary.
If the generations on primary setting causes the GDG to be held on
primary for more that Level1 days, this could cause your situation. When
Try adding CEE.SCEEH.NET.H
CEE.SCEEH.NETINET.H
to your source or syslib concatenation.
snip
I'm trying to compile the FTPD exit FTPOSTPR unchanged from the
SEZAINST library. It's CS 1.8.
I get a lot of compilation errors:
/snip
ERROR CCN3045 T7516.UD0.C(FTPOSTPR):220 Undeclared identifier
AF_INET6.
The definition for AF_INET6 on my z/OS 1.9 system appears to be in
'TCPIP.SEZACMAC(EZAAB08N)'.
That may cure the problem (at least one of them). The rest of the errors
posted may or may not be secondary effects of the
Along those same lines, the TCPIP dependency on VTAM for startup should
also be looked at.
snip
Mark,
You gave me just too good an opening for me not to exploit it... :-)
I happen to be working on a project to reduce start-up times on z/OS and
one
of the things I've been looking at is the
For those that missed it, Gwen Dente will be giving her free Workshop: PCI How
z/OS Comm Server can help.
Having attended, I can highly recommend this workshop. About ¼ is the Payment
Card Industry standard itself, and the remainder are the technical pieces of
z/OS and Comm. Server that
Check for co-incident processing. E.g. SMF and RMF (both) synchronized
on the hour. This has been know to cause spikes when everyone is trying
to do everything all at the same time.
DDCONS=YES for a long running system task (e.g. DFHSM) that was
terminated.
Perhaps a high priority batch job
Why go through Node Y at all? Use JES2/TCPIP and connect directly to JES3/TCPIP
on Node Z. Or am I missing something here?
snip
Subject: Routing a NJE connection via another NJE node
We have two companies (nodes X and Y) that connect to the same remote NJE node
(Z) via SNA, using the old
NOPE!
-Original Message-
From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On
Behalf Of Donnelly, John P
Sent: Monday, January 12, 2009 10:14 AM
To: IBM-MAIN@bama.ua.edu
Subject: MAXUSER=250
MAXUSER=250, SYS TASKS PLUS INITS PLUS TSOUSERS
We implemented
MAXUSER does NOT EQUAL USERMAX.
MAXUSER is total number of address spaces allowed (STC, BATCH, OMVS,
TSO, ...). USERMAX applies only to TSO.
snip
YES!
Console command:
F TSO,USERMAX=500 (for example)
It will change the amount. But you need to change the VTAM number of
entries to
That should work just fine. I do the same thing with DFDSS copy/rename.
BTW, in my sandbox, I have a permanent set of OMVS files that I apply
maint to (SMPE is updated to point to OMVS.SERVICE.*) the files are then
copied with rename back to the sysres volumes.
snip
I have a question about OMVS
It seems to me that ordinary LPAR weights will do the trick. They will
allow excess capacity to be used by any/all LPARs, but enforce a max
proportional to the LPAR weight when the CEC reaches full utilization.
Set the weights proportionally and you should be good to go.
What to do about the
Are you sure you have the correct UCAT.
Is the entry found in CATALOG.MVSICF1.VCAC1AB.
Try LISTC ENT('PSI.SI8470B.TRN.G0088V00') ALL
Change the CATALOG parameter to the correct UCAT.
Better yet, omit the catalog parameter entirely.
HTH,
snip
IDCAMS SYSTEM SERVICES
See OA11898: The key is the IDC3009I message:
Use idcams delete w/recovery option.
CATBREAKER - A GDS entry may not be created when rolling of a
GDS entry and the new GDS entry must be put into an extension
record. DIAGNOSE reports a Reason 28 - GAT CELL ENTRY NOT
FOUND. This should only occur
I haven't looked, but I would suspect not. This code and logic dates
from OS/MVT days.
I cannot think of any way to eliminate the message short of a SYSTEM
mod.
The message can be suppressed from the console via the MPF processing
facility and in a clist via CONTROL NOMSG. Not sure off the top
RMF post processor: SYSRPTS(WLMGL(SCLASS,SCPER)). Vary the amount of
input data as required.
Also the RMF Spreadsheet Reporter
http://www-03.ibm.com/servers/eserver/zseries/zos/rmf/tools/#spr_win
snip
I'm looking for a program or tool to help me generate a report to show
the use
of service
snip
Subject: Re: z10 toleration maintenance
We have six zos 1.7 systems three on a z890 and three on a z9 we have
applied the toleration for the z10 on the z890 systens since we will be
replacing the z890 with the z10 all six
Systems are in a sysplex do we have to apply the z10 maintenance onto
I mis-read the original post. I thought the z9 was being replaced, not
the z890. Having re-read the OP, I would say the toleration maint is
mandatory for the z/890 LPARs, and highly desireable for the z9 LPARs.
Apologies to the OP.
snipSubject: Re: z10 toleration maintenance
Staller, Allan
Yes
snip
Subject: Re: Deleting UnExpired dataset using JCL
Dave,
Are you saying that there is no way to do this using pure JCL?
I know about IDCAMS, but the user wants a pure JCL solution.
In that case I think you will have to use one of the many PARM to control
card programs to
See SYS1.SAMPLIB(ARCSTRST). Find for IEBDG
IEBDG generates a single record that is Loaded into the SDSP in the next
step.
HTH,
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED]
Just roughing it out:
600K tracks * 1 vol/56k tracks * 2.8gb/vol = 30 GB
So, probably not without a CF upgrade
snip
...Our current CF has 8 GIG.
... Remainder snipped
/snip
.ua.edu/archives/ibm-main.html
--
For IBM-MAIN
snip
Just went live with z/OS 1.7 and noticed that CPU consumption by
Omegamon/MVS has gone up dramatically (CMS and HIST tasks) like +50% or
4 to 6 MIPS (FSVO MIPS.
/snip
In 30+ years with various flavors of OM, I have found that there are
really only 2 things that seem to matter.
1) Auto
You forgot the Borg!
snip
Actually, I did, a the back-of-the-envelope risk analysis indicated that
the likely delay of 6.2 million years before likely exposure was deemed
acceptable, interstellar terrorism by the Romulan Empire and Vogon
constructor fleets notwithstanding.
/snip
Issue the equivalent HSM command to make the change dynamically,
Restart HSM later (at your convenience) to make solidify the change.
/F DFHSM,HSM command goes here
HTH,
--
For IBM-MAIN subscribe / signoff / archive access
snip
Alan...what would be he HSM refresh command?
/snip
There is no mechanism to refresh ARCCMDxx in entirety. The only way to
do that is to restart HSM.
The method used is to issue individual HSM commands to accomplish the
same
changes made to ARCCMDxx. E.g. ADDVOL, SETSYS, .
There are
Not a good way to win more friends (or customers) on this list!
snip
CA sues over mainframe software copyright infringement
[Mark Fontecchio, News Writer]
Software giant CA has filed a $200 million lawsuit against Rocket
Software,
claiming the company stole its source code to build IBM DB2
I am saying Rocket Software is (most likely) more highly regarded than
CA
on this list! The individual CA contributors notwithstanding, CA has
IMO a deservedly poor reputation with regards to customer relations.
Witness the number of shops that have attempted to eliminate all CA
software.
CA
CA for suing. Just another (IMO) episode in CA's history of poor
customer relations.
snip
I'm not sure I understand you. Or you upset with CA for suing or Rocket
for
the possible infringement of copyrights if the charges are proven in
court?
Tom
/snip
Also ref. Apple v. Microsoft
snip
Ref: SCO vs. IBM
/snip
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at
snip
Come on folks - CA like any company has an obligation to protect its
assets. I don't know if their suit is valid or not and will not comment
on
the merits of the suit. However CA would be doing a disservice to its
share holders if they did not pursue any/all actions to protect this
And they still haven't learned!
snip
.But that was typical of CA of that era.
/snip
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Goes to show bean-counters should never be allowed to run corporate
policy...
Amen Brother
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Steve,
Try this link from Phil's site
http://www.isham-research.co.uk/mainframe_2008.html
Phil,
snip
How does one find the material alluded to in the last paragraph?
/snip
--
For IBM-MAIN subscribe / signoff / archive
The 470C in error status seems to be perm IO error reading or writing a
DSCB.
Is your VTOC full?
snip
DSNJ103I -DB71 DSNJDS01 LOG ALLOCATION ERROR 761
DSNAME=DSN71.ARCHLOG1.B0001449, ERROR STATUS=470C107F, SMS REASON
CODE=
DSNJ115I -DB71 OFFLOAD FAILED, COULD NOT ALLOCATE AN
Add another service class period with very low (or non-performing goals)
to
the affected service class. When the user(s) reach the Service Unit
Limit and drop into the last period. Very little or no service will be
consumed.
You will probably have to experiment to find the correct Service Unit
SNIP
snip
bwstorts [EMAIL PROTECTED] wrote in message
news:[EMAIL PROTECTED]...
We would like to basically quiesce or severely limit a job or tso id
once it has used a certain amount of cpu. anyone know how to do
this?
Resource groups don't work, since everyone in the resource group
gets
Did previously. No longer.
There were no problems in our experience.
snip
We are upgrading from a 2064 to a 2096. Our 2064 SYSPLEX contains one
LPAR running z/OS 1.4. Is anyone running z/OS 1.4 on a 2096? If so,
any
problems or suggestions? Thanks.
/snip
Look for the dataset to be cataloged in 2 different user catalogs
This must be done by a LISTCAT for each individual usercatalog.
ISPF 3.4 cannot do this. It must be IDCAMS LISTCAT.
Try LISTCAT ENT('your.dataset.name') ALL CAT('your.usercatalog.here')
either online or in batch.
*ONCE FOR EACH
1 - 100 of 947 matches