Re: Production Jobs contention with Test Jobs

2006-03-13 Thread Lizette Koehler
(that is, allocation requests specified in the job's JCL). Default: NO This may bring your enqueue to the forefront and allow Operations to recognize it more efficiently and cancel the test jobs. Lizette Koehler -- For IBM-MAIN

Re: Batch TMP RECFM(VB) Input

2006-03-14 Thread Lizette Koehler
would still be typing now. Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm

Re: Batch TMP RECFM(VB) Input

2006-03-14 Thread Lizette Koehler
, you maybe able to remove the requirement of numbers cols 1-8. That means no CNTL, TEXT, etc.. type of file. Make a new one, like MYVB. So your new file might be called TSOID.JCL.MYVB Lizette Koehler -- For IBM-MAIN subscribe

Re: CICS down after transaction exec wait macro.

2006-03-24 Thread Lizette Koehler
. Not sure if this helps. If I had a dump to look at, I could see if this applies or not. If this is the case, then I would ask what has changed. Any code changes, ptfs installed, the normal drill. Lizette Koehler

Re: CICS down after transaction exec wait macro.

2006-03-24 Thread Lizette Koehler
. Not sure if this helps. If I had a dump to look at, I could see if this applies or not. If this is the case, then I would ask what has changed. Any code changes, ptfs installed, the normal drill. Lizette Koehler

Re: Over my head in a JES exit

2006-03-31 Thread Lizette Koehler
Steve, you do not think that IBM would create a situation where they could charge money to fix it? I thought not. Lizette -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with

Re: PDS unload

2006-04-05 Thread Lizette Koehler
Gerry, If you have SAS in shop, then try PROC SOURCE. It will unload a PDS and create IEBUPDTE control cards in the offloaded file. Lizette -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to

Re: S913 Abend

2006-04-06 Thread Lizette Koehler
that prevent you from using this facility. Don't forget to turn it off when you are done. $TDEBUG,SECURITY=NO Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED

Re: Status Of DASD Unit

2006-04-24 Thread Lizette Koehler
Willie, If you look up the message ID (should be like an IEE message) with this display you would find that it means that the dasd unit is offline. NRD means not ready. So you need to have someone vary the device online. If that does not work, then you would need to have someone do a display of

Re: Redirect the joblog to mvs syslog when job abend ?

2006-04-30 Thread Lizette Koehler
, and start and end messages. Lizette Koehler Looking for any alternative to redirect the joblog to mvs syslog when job abend , Is it doable ? -- For IBM-MAIN subscribe / signoff / archive access instructions, send email

Re: where this command comes from ?

2005-05-24 Thread Lizette Koehler
Is it possible that one user has a command defined on the LOGON PANEL Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO

Re: JOB card error - it has me stumped.

2005-05-28 Thread Lizette Koehler
be flushing the job and not JES or Converter? Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http

Re: Userids

2005-05-31 Thread Lizette Koehler
. Personally, I would stay with a 7 char or less TSO ID. That way you can avoid any gotcha code, processes, or products. Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL

Re: Userids

2005-05-31 Thread Lizette Koehler
ID. Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html

Re: GDG gen existence check via JCL

2005-06-01 Thread Lizette Koehler
I think if you are listing a level of data sets with LISTC you use LISTC LEVEL(dataset name) Then it should produce an RC=0 I don't have a system to check this, but I think it is correct. Lizette Koehler -Original Message- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED

Re: Can we measure cpu use of a JES2 Exit

2005-06-08 Thread Lizette Koehler
Has anyone checked to see if the $DPERFDATA(*) (I think that is it) command would help? I don't have access to JES2 at the moment, but do remember using it to get a vast amount of internal statistical data out of JES2 with it. Lizette Koehler

Re: Volume Problem - z/OS 1.4

2005-06-10 Thread Lizette Koehler
products that assist SMS in managing DASD, like PROSMS, you could check with those vender(s) first. Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message

Re: Mistakes in migrating - need to clear DASD volumes

2005-06-12 Thread Lizette Koehler
it to the system, using an IMPORT CONNECT command. The parameters are: G87UCAT identifies the object to be disconnected. DISCONNECT identifies the object as a user catalog. When a user catalog's connector entry is to be deleted, DISCONNECT is required. Lizette Koehler

Re: SMS managed PDS can't added to lnklst,csv538I,multi-volume dataset not allowed

2005-06-13 Thread Lizette Koehler
-volume data sets being SMS defined as multi-volume even though they were not multi-volume data sets and could not be multi-volume. Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL

Re: NO DATA SETS AUTHORIZED in SDSF?

2005-06-17 Thread Lizette Koehler
? Or activated RACF security for SDSF by activating the SDSF Resource Class? Is the SDSF Started Task Running? Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED

Re: z/OS stand-alone dump

2005-06-22 Thread Lizette Koehler
Jason, If you mean the basics - z/OS V1R4.0 MVS Diagnosis: Tools and Service Aids Otherwise, you could use the online bookmgr z/OS 1.4 bookshelf and search for what you are looking for: http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/Shelves/IEA2BK34 Lizette Koehler --- Snip What

Re: How to know the z/OS version by TSO login.

2005-06-22 Thread Lizette Koehler
If you use ISPVCALL you need to enter it twice. The first execution collects the data and the second displays the output. Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL

Re: Help on SC03 abend

2005-06-22 Thread Lizette Koehler
If my old addled brain is thinking correctly, I believe over 10 years ago IBM decided to no longer be nice to programs and require that all programs close any files they open. And if they did not close them, the system would then issue a SC03 abend. Or am I getting too forgetful??? Lizette

Re: ILR005E PLPA PAGE DATA SET FULL

2005-07-25 Thread Lizette Koehler
From what I recall, that message is okay. The performance guys at my shop always made it overflow. That way they knew they did not have wasted space in PLPA. So, AFAIK, unless there are new rules, I don't think this is an issue. Lizette Koehler

Re: utility to print PDS list?

2005-07-25 Thread Lizette Koehler
Well, if you have SAS, it can do it. Otherwise IEBPTPCH can do it. It all depends on the intent of the listing and the format you need. There might even be something on the CBT tape that might provide you with a PDS print function. Lizette Koehler

Re: EOF at Beginning of PDS

2005-07-27 Thread Lizette Koehler
that might have a FIX command in it. See link: http://www.cbttape.org/freepds.htm Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO

Re: DFHSTUP abend

2005-08-23 Thread Lizette Koehler
what a U0001 indicates. Or go to the CICS list server and check with them or scan their archives. CICS List [EMAIL PROTECTED] Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL

Question on DCOLLECT data

2006-08-25 Thread Lizette Koehler
. Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html

Uncataloged VSAM in SMS Pool

2006-08-28 Thread Lizette Koehler
not delete the entries. Just leave them on the volumes uncataloged? Thanks for any insight. Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET

Re: Systems Programming Position - Raleigh/Durham NC

2006-09-07 Thread Lizette Koehler
? Lizette Koehler -Original Message- From: Todd Blandford [EMAIL PROTECTED] Sent: Sep 7, 2006 9:39 AM To: IBM-MAIN@BAMA.UA.EDU Subject: Systems Programming Position - Raleigh/Durham NC Hello all - I have received permission to post this from the list owner. We have an immediate opening

Re: Where is the DB2-L List?

2006-09-12 Thread Lizette Koehler
Here are the instructions from the DB2-L list. Welcome to the IDUG DB2-L list. To unsubscribe, go to the archives and home page at http://www.idugdb2-l.org/archives/db2-l.html. From that page select Join or Leave the list. The IDUG DB2-L FAQ is at http://www.idugdb2-l.org. The IDUG List

Re: IEHLIST LISTPDS in an SMS environment

2006-09-18 Thread Lizette Koehler
. (I was thinking you could just drop the VOL= parm and realized that only if the data set resides on the SYSRES volumes would that work). Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send

Re: Production DB2 Problem

2006-09-20 Thread Lizette Koehler
of ADDVOL and DB2 extensions. I know at some point, IBM correct the ADDVOL in DB2 to get another UCBEXT without have to cycle or reorg the data base. The DB2 List might have better information on this issue. Lizette Koehler I am facing problem in production DB2. 5 Volumes were configured

Re: IPL with future date

2006-09-21 Thread Lizette Koehler
What kind of testing are you trying to do? There are date simulator products like HOURGLASS or I think Compuware has one. With these products your applications can pick a date and time to run in and not affect the rest of the environment. Lizette -- Snip

Couple Dataset and Resizing

2006-10-06 Thread Lizette Koehler
Hi, running z/OS V1.4 Need to refresh my memory on how to resize a couple data set pair. Ran into an issue where I attempted to create a new policy for my CFRM and it died saying I had more than 50 Structures IXC736I THE LIMIT OF 50 STRUCTURES PER POLICY HAS BEEN

Re: backup mastercatalog

2006-10-08 Thread Lizette Koehler
The task you ran got an S878 which is usually a REGION size issue. You need to make the region= parameter on this task BIGGER. You can use tools like LOOKAT to find out what system abend or error messages mean. Lizette Koehler -Original Message- From: IBM Mainframe Discussion List

Re: Space Abend - Stumped

2006-10-09 Thread Lizette Koehler
I guess a couple of questions would be What is the primary and secondary allocation? From the listing it looks like the data set went to 16 extents and died. Perhaps a change on the primary or secondary space allocation would be needed? Lizette

TRSMAIN and Tape

2006-10-12 Thread Lizette Koehler
I was going to use TRSMAIN to pack some SMF Data from TAPE data set to dasd for FTP process. However the documentation for TRSMAIN states it cannot use tape. I do not understand why this is the case. What is special about TRSMAIN and tape processing. I would have thought it would just be

Re: *$HASP050 JES2 RESOURCE SHORTAGE OF JOES - 100% UTILIZATION REACHED

2006-10-12 Thread Lizette Koehler
Joes can be dynamically increased with a $TOUTDEF command. I would also investigate what was generating all the SYSOUT. JES2 creates one JOE for every SYSOUT in a job. So if you have a SYSOUT=A and a SYSOUT=B that is 2 JOES for that job. You also create jobs depending on the OUTPUT

Re: $T PROCLIB

2006-10-16 Thread Lizette Koehler
Just one question. Are your proclibs defined on the PROCLIB statement inside the JES2 Parms? I think $TPROCLIB only works for them and not JCL'd Proclibs. If they are, this will work okay. Though I would be the only TSO User Logged on during this process incase there are any issues. As for

Best way to monitor CF and Structures in CF

2006-10-16 Thread Lizette Koehler
I have a task to create monitoring reports on the CF and Structures in the CF (DB2 Group Buffer Pools). Tools I have available are RMF, SMF, MXG (oh and TMON). What is the best way to create the reports that will show growth, activity, etc... I am not a capacity planner so this is new to me.

Re: IBM 3Q2006 Earnings: Mainframes Strong (Again)

2006-10-18 Thread Lizette Koehler
While I was out of work for 18 months, I used MONSTER, HOTJOBS, and Careerbuilder. I applied to all the positions I thought I qualified for, but employers either never got back to me, had me out on an interview and never got back to me, or said my skill set was too old (my last os at the time was

Re: LE Defaults for z/OS UNIX

2006-10-18 Thread Lizette Koehler
While I'm waiting for a response from MVS-OE, can somebody here point me to where the LE Installation Defaults are specified for z/OS UNIX? I don't find it in either the z/OS UNIX doco or the LE doco. This is for z/OS 1.5, btw. TIA, -jc- The LE Options are tuned according to HEAPS,

Re: IBM 3Q2006 Earnings: Mainframes Strong (Again)

2006-10-18 Thread Lizette Koehler
How can I get your job I had to move to South Carolina to get this gig. They will not even consider work at a distance. I asked my last boss if I could do full time work at home for the same salary I got here and they said no. So where is this wonderous, intellegent organization you work

FileSeq Number on Tape

2006-10-23 Thread Lizette Koehler
Ok, here is a very basic question: When I code the FILESEQ number on a Tape - it failes if I used hi order zeros. So it will not take 0001 but will take 1. I did not remember this being a restriction in JCL. At what point in the converter code would look at this and not like 0001.

Re: FileSeq Number on Tape

2006-10-24 Thread Lizette Koehler
Resolution: I had written a REXX exec for a DR process that would read the TMSGRW report of volumes being taken to the DR site and generate a series of FDR Full Volume Restores. I was unable to test the actual JCL and so made some BIIIGGG asumptions. The FileSeq number generated was a 5

Re: DUMPSPACE in Coupling Facility

2006-10-26 Thread Lizette Koehler
The use of Volatile really (in my opinion) deals more with DB2 Data Sharing than anything else. If you set the CF to Volatile YES - the DB2 Data Sharing Regions put out a message DSN7507I :DSNQ DSN7LSTK 737 SCA STRUCTURE DSNSB0Q_SCA IS ALLOCATED IN A

Re: DASD STATUS - F-NRD

2006-10-27 Thread Lizette Koehler
Here is my 2 cents worth. The only issue here is whether or not the device is offline. If there is an F it is offline. I believe the NRD is a throw back to the old days when you could flip a switch that would READY or NOT READY the physical drive. That is no longer valid with RAID, Shark and

Re: Meeting in Parsippany

2006-10-27 Thread Lizette Koehler
I did not find a flyer. Can you let me know where on the web I can download it? Thanks Lizette -Original Message- From: August Carideo [EMAIL PROTECTED] Sent: Oct 27, 2006 1:41 PM To: IBM-MAIN@BAMA.UA.EDU Subject: Re: Meeting in Parsippany This just passed: I wanted to let you

TPX and Logon Scripts

2006-10-30 Thread Lizette Koehler
Anyone out there have customized TPX with logon scripts that can help me make them work? CA has not been very helpful on this issue and I am losing my hair (not really) over this. I read the manuals and do not get very far because I am not VTAM or CICS fluent (trying to make CICS Autoinstall

Re: SYSLOG Broken

2006-11-01 Thread Lizette Koehler
Not sure what your abend in SDSF is, but it is possible that the HASPINDX used by SDSF is cluttered. See how many SYSLOG data sets you have out on SPOOL. I think you can use the ST command and prefix SYSLOG. Or you can review the size of the HASPINDX data set and you may need to increase the

Re: Oracle on z/OS

2006-11-01 Thread Lizette Koehler
Already a DB2-L newsgroup Welcome to the IDUG DB2-L list. To unsubscribe, go to the archives and home page at http://www.idugdb2-l.org/archives/db2-l.html. From that page select Join or Leave the list. The IDUG DB2-L FAQ is at http://www.idugdb2-l.org. The IDUG List Admins can be reached at

ex-CEO of Computer Associates goes to prison

2006-11-02 Thread Lizette Koehler
Found this on the news net and thought I would pass it along. http://news.yahoo.com/s/ap/20061102/ap_on_bi_ge/software_sentence By TOM HAYS, Associated Press Writer 20 minutes ago NEW YORK - The former chief executive of Computer Associates International Inc. was sentenced to 12 years

End of days for the Sysplex Timer

2006-11-04 Thread Lizette Koehler
) Planning Server Time Protocol (STP) Recovery Considerations (90 minute long session) Server Time Protocol (STP) User Experiences Migrating to STP in the Development Lab Server Time Protocol (STP) User Experience at a customer Lizette Koehler

Re: Question JQES utilization

2006-11-05 Thread Lizette Koehler
in JES2. Lizette Koehler ([EMAIL PROTECTED]) -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu

Re: Combine spool output datasets

2006-11-07 Thread Lizette Koehler
Could you be more specific? Are you looking to place these in a data set, or print them as a unit? Or are you looking to change them with an OUTDEF parm or similar function? The JESMSGLG, JESSYSMSG, and JESJCL should all fall under the MSGCLASS parmeter. Lizette Hi Is there any

z/OS V1.4 and v1.7 with Language Environment

2006-11-08 Thread Lizette Koehler
We are planning to upgrade from z/OS V1.4 to V1.7. There has come up a concern over having z/OS V1.7 Language Environment in the TEST/DEVL systems and not in production. That programs compiled and LKED with the newer LE would have issues running in the V1.4 LPARS. I was thinking of just

Re: IPL with CLPA

2006-11-08 Thread Lizette Koehler
I know you can specify D PROG,LPA,MOD=xx to see if a specific LPA Modules is loaded. There are probably some other tools that will do a more interrogation of LPA. LIzette -- For IBM-MAIN subscribe / signoff / archive

Re: z/OS V1.4 and v1.7 with Language Environment

2006-11-08 Thread Lizette Koehler
Thanks everyone. I had read the manual and reviewed the processes. Unfortunately there are some that are very nervous about this upgrade. I was just trying to find another method that would make them feel warm and cozy. And to do that, I thought keeping the SCEELKED* data sets back a level

Re: How to expand SYS1.LINKLIB?

2006-11-10 Thread Lizette Koehler
Depending on this module, you might be able to temporarily move it to another data set in the LINKLST and use it until you can get the SYS1.LINKLIB fixed. But only if the fix is urgent enough to install. Or look at MLPA as an alternative until you get SYS1.LINKLIB fixed. If it isn't urgent,

Re: Suppressing Step Status Messages

2006-11-15 Thread Lizette Koehler
Looking for a way to suppress Step Status messages from my master consoles. Any suggestions? A couple of other options, If you have an automation tool - Netview, Tivoli, OPS/MVS, etc you can probably have that capture and not send the message to the console, or talk sweet to your mvs

Re: How to... define VSAM to 2 lpars

2006-11-27 Thread Lizette Koehler
Is the VSAM dataset in a USER Cat that both systems can see? If so, then you just need to make sure your SHROPTs are compatible with mutliple systems view/update it. Lizette -- For IBM-MAIN subscribe / signoff / archive

EMC Dasd Question - A little OT

2006-11-27 Thread Lizette Koehler
I am looking to see if anyone is using the EMC DMX3000 box for the mainframe? If so, are you using AUTOSWAP? Just looking for some input. We are thinking of using it. You can write me offline at [EMAIL PROTECTED] Lizette

Re: Z/Os Storage Mgmt products

2006-11-28 Thread Lizette Koehler
You might also want to check out the DTS software group. It has several storage products like those described. Lizette Hello, does anyone know similar products to CA-Vantage Storage Resource Manager ??? What CA-Vantage does is: BrightStor CA-Vantage Storage Resource Manager manages, monitors

Re: SDSF authorizing

2005-10-04 Thread Lizette Koehler
John, Have you tried trying on tracing in JES2 for security? It might provide ACF2 messages that could help in identifying this issue? Lizette Koehler - Original Message - From: John C. Wolf [EMAIL PROTECTED] Newsgroups: bit.listserv.ibm-main To: IBM-MAIN@BAMA.UA.EDU Sent: Tuesday

Telecommuters beware the tax man

2005-11-03 Thread Lizette Koehler
adopts a bill protecting them, experts said Tuesday. http://news.com.com/Telecommuters+Beware+the+tax+man/2100-1028_3-5927124.html Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email

Re: JCL/Restart Question

2005-11-05 Thread Lizette Koehler
can omit the outer parentheses if you code only the first subparameter. ° The RESTART parameter cannot have a null value. Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions

Passing PARM to Cobol

2005-11-08 Thread Lizette Koehler
Craig, The hex 40C makes me think you have the length field incorrectly coded. Should it be a COMP-3 field instead of a BINARY field? Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send

Re: Passing PARM to COBOL.

2005-11-09 Thread Lizette Koehler
before or after the /. However, there is another interesting (and new to me) comment at: publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/ceea5160/2.2.2.8.1 Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive

Re: Command to stop queue of the jes2

2005-11-11 Thread Lizette Koehler
, everything depends on what you want to do with halting your environment. By init class, by member in a MAS or by specific types of jobs (INPUT, CONVERTER, etc...) Hope this helps. Lizette Koehler -- For IBM-MAIN subscribe / signoff

Re: To know how a data set is protected by RACF

2005-11-19 Thread Lizette Koehler
set I am interested in. Or issue LD PREFIX(md0006.tools) g This will attempt to list any generic profiles Of course you may not have necessary racf authority for listing everything. Lizette Koehler -- For IBM-MAIN subscribe

Re: Looking for a copy of Advanced Assembler Language and MVS Interfaces : For IBM Systems and Application Programmers 1999

2005-11-22 Thread Lizette Koehler
What is amazio? Is it suppose to be amazon? Interfaces : For IBM Systems and Application Programmers 1999 FYI book aval now at amazio Lizette -- For IBM-MAIN subscribe / signoff / archive access instructions, send

Re: Introducing delay in a assembler.

2005-11-25 Thread Lizette Koehler
was actually generated by your system. Provide the output a couple of lines before and after the area of interest. Hope this helps, Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL

Re: START fails no diagnostics!

2005-12-06 Thread Lizette Koehler
in any other queue under SDSF except for ST on that jobtask name. The dynamic SVC dump name would depend on your definition in your environment. You can display the dumps via D D,ST (Display Dump,Status) both dynamic dumps and SYS1.DUMPxx data sets will be displayed. Lizette Koehler

Re: 'ALLOCATE' a data set in my TSO/E session

2005-12-08 Thread Lizette Koehler
CLIST and REXX execs that run in Batch or TSO. Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http

Re: 'ALLOCATE' a data set in my TSO/E session

2005-12-08 Thread Lizette Koehler
I got a little confused. Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives

Re: Bang!

2005-12-13 Thread Lizette Koehler
I was able to access both sites Steve. Not sure what your problem is ;-) Lizette For both of these URIs I got domain_name could not be found. Anyone else have that problem? Kind regards, -Steve Comstock -- For

Help with doing Contract Work as a Sys Prog

2005-12-28 Thread Lizette Koehler
to know any gottcha's that might hit me (taxes, FICA, medical, etc.) that I have not thought of. The contract company tells me it is W2 without benefits. I appreciate any input. Please contact me at [EMAIL PROTECTED] Lizette Koehler

Re: Assembler training / books?/

2005-12-29 Thread Lizette Koehler
be more accessible. Hope this helps. Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http

Re: Define and start JES2

2006-01-03 Thread Lizette Koehler
for each image, but during our roll out procedure, it was renamed to JES2 on the target system. That way we could maintain all of our environments in one staging Proclib. Hope this helps. Lizette Koehler -- For IBM-MAIN subscribe

Re: Move HASPINDX dataset?

2006-01-04 Thread Lizette Koehler
The HAPSINDX needs to be deallocated to all TSO sessions. What I do is use the SDSF Server to move it. Alter ISFPARMS to point to new HASPINDX F SDSF,REFRESH Ensure all TSO allocation to old file are gone. TSOENQ function is used to do this. Delete old file. If you do not use the SDSF SERVER,

Re: FFST Abend at Startup

2006-01-13 Thread Lizette Koehler
Pat, You can create a dummy member called EPWHWR01 (hardware probes) by just editing a member and put a * in column 1 (that is the comment card) and save it. Then try restarting FFST again. Lizette Koehler -- For IBM-MAIN

Re: LINKLST into EXTENTS

2006-05-04 Thread Lizette Koehler
added something on the fly, did not tell anyone and then BOOM we had a fun time trying to determine what changed and how to back it out. Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access instructions, send

Re: Syslog range recording DB2 V7.1

2006-05-19 Thread Lizette Koehler
://www.idugdb2-l.org. The IDUG List Admins can be reached at [EMAIL PROTECTED] Find out the latest on IDUG conferences at http://conferences.idug.org/index.cfm Lizette Koehler -- For IBM-MAIN subscribe / signoff / archive access

JES2 JOEs and How to Identify them

2006-06-09 Thread Lizette Koehler
It has been awhile since I had to trouble shoot this type of problem. Does anyone know of a way in JES2/SDSF to identify the job that has produced a significant number of JOEs? I had a situation where we ran out of JOEs. Other than reviewing the entire output queue manually, is there an

Confusion on output of LISTC CAT

2006-06-20 Thread Lizette Koehler
Hi all, I seem to have forgotten what it means when the output from an IDCAMS LISTC CAT('catname') has some of the information as (INVALID). And for some reason it is eluding me when I review the SMS manauls If you look at my output it has (INVALID) for entries like CI-SPLIT, CA-SPLIT and

Re: Confusion on output of LISTC CAT

2006-06-20 Thread Lizette Koehler
Thanks Mark. that is the answer I needed. We are running z/OS V1.4 and this fits very nicely. We will be upgrading to z/OS V1.7 by end of year. So I will probably just live with this anomaly for now. Lizette Yes - install APAR OA11927. Thanks, Mark Thomen Catalog/IDCAMS/VSAM

Re: Confusion on output of LISTC CAT

2006-06-21 Thread Lizette Koehler
The Catalog was created before the IMBED was removed. Any catalog created with IMBED before then would still show it in the listing. If you apply the apar OA10952 and then do the EXPORT/IMPORT the IMBED will no longer be in the listing. You can consider it an artifact from when the catalog

Example code for CEEBXITA

2006-06-26 Thread Lizette Koehler
an example of the control blocks I needed to chase and exclude (Exclude STC, and TSU, only do it if Batch), but cannot find my notes. It would save me some time if someone had it coded this way that I could borrow to make sure I do not over shoot my goal for the exit. Thanks in advance. Lizette

Re: compress a proclib

2006-08-02 Thread Lizette Koehler
I think there are actually a couple of solutions here. 1) Do not put user proclibs in JES2. Use the JCLLIB statement instead. 2) If you do put a user proclib in JES2 then make it with only primary allocation and no seconday. Allow for growth. If it fills up then use the JCLLIB statement 3)

SVC Dumps and DB2

2006-08-03 Thread Lizette Koehler
Does anyone know if there is a way to reduce the amount of information DB2 feels it needs to dump when it requests an SVC Dump? We had MAXSPACE set at 4500M and it still was not enough. I do have the Dump Data sets SMS managed and STRIPPED (extended format) so that part should not be a

Re: SVC Dumps and DB2

2006-08-08 Thread Lizette Koehler
Thanks Sam, and everyone else. We have no issue with the DASD part of the dump. I have that setup as stripped. It is just the virtual dump I am having difficutly with. We have limited storage and so our MAXSPACE can only go to about 4.5G. The 6G or 8G is out of the question right now. I

Re: SYSTRACE in SYSMDUMP

2007-11-16 Thread Lizette Koehler
I woudl probably verify what I dump to SYSMDUMP. You can do this with a D D,O command. You should see something like the following IEE857I 10.13.16 DUMP OPTION 713 SYSABEND- ADD PARMLIB OPTIONS SDATA=(LSQA,TRT,CB,ENQ,DM,IO,ERR,SUM),

Re: VTS Scratch Count Issue

2007-11-22 Thread Lizette Koehler
The only other area I might also consider is your backend tapes for the VTS should you decide to add more virtual tapes. Make sure you have enough of them to support any additions you might make to the VTS. Lizette There are two main ways to tackle this situation, and likely you will need

Re: ISMF Question

2007-11-22 Thread Lizette Koehler
Kees, If you play around with this you could discover that a blank entry can only be used in a very specific configuration. And I always do recommend anyone with a question first start by playing with a construct (not the production ones of course) and see what it does. For example if you

Re: Excel Question

2007-12-05 Thread Lizette Koehler
Ed, What are you trying to do in EXCEL that WORD will not do? I usually use the WORD MAIL MERGE feature to create address lists. You can mail merge EXCEL data into a WORD document to create Letters, mailers, directories, etc. Lizette -Original Message- From: Ed. Benoit [EMAIL

Re: FTPing of DFDSS Dump Files

2007-12-06 Thread Lizette Koehler
When I use DFDSS to download a volume or dataset(s) to be transferred to another host, I always include BLKSIZE=32760 on the output file in DFDSS. Even though DFDSS does not care, it does help my transfer process whether that is NDM, XCOM, FTP. If you terse the file you need to make sure you

TPX Acl/e Code and Dispatch

2007-12-06 Thread Lizette Koehler
Does any kind soul out there have a DISPATCH logon script for TPX ACL/E language? I am running into issues and cannot seem to get my arms around a solution. I have one user that seems to be already logged on but when we look they are not logged on to DISPATCH. My script works for everyone

Re: TPX Acl/e Code and Dispatch

2007-12-06 Thread Lizette Koehler
I can emulate the problem by using two different IDs to logon to TPX Sessions and logging on with the same id in Dispatch. So TPX Session one is logged on as USER1 adn TPX Session two is logged on as USER2. I then logon to DISPATCH under both TPX sessions as USER1. This creates the error

Re: TPX Acl/e Code and Dispatch

2007-12-06 Thread Lizette Koehler
It is just odd that I only have one user that has this duplicate logon issue. No one else here is reporting it. I am trying to get more users on TPX. And hopefully we can see if this is isolated or not. Well, we have IPLs scheduled for this weekend so I will see if monday it is cleared up.